Specifications
Notes
(1) Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
(2) 220V
(3) 230V
(4) 240V
(5) EER/COP according to Eurovent 2012, for use outside EU only
Seasonal efficiency
(according to
EN14825)
Cooling
Energy label
A+
Pdesign
kW
2.50
3.50
SEER
5.74
5.60
Annual energy
consumption
kWh
152
219
Heating (Average
climate)
Energy label
A+
A
Pdesign
kW
2.60
2.90
SCOP/A
4.56
3.93
Annual energy
consumption
kWh
798
1,033
Piping connections
Liquid
OD
mm
6.35
Gas
OD
mm
9.5
Drain
OD
mm
20.0
Heat insulation
Both liquid and gas pipes
Current
Nominal running
current (RLA) - 50Hz
Cooling
A
3.72 (2) / 3.51 (3) / 3.40 (4)
5.09 (2) / 4.88 (3) / 4.68 (4)
Heating
A
4.50 (2) / 4.30 (3) / 4.10 (4)
5.90 (2) / 5.60 (3) / 5.40 (4)
Nominal efficiency
EER
4.12 (5)
3.30 (5)
COP
4.42 (5)
3.78 (5)
Annual energy consumption
kWh
303
530
Energy label
Cooling
A
Heating
A
2-6 Capacity and Power input
FLXS25B/RXS25L3
Indoor unit
FLXS25B
Outdoor unit
RXS25L3
Cooling capacity
Min.
kW
1.2
Btu/h
4,100
kcal/h
1,030
Nom.
kW
2.5 (1)
Btu/h
8,500 (1)
kcal/h
2,150 (1)
Max.
kW
3.0
Btu/h
10,200
kcal/h
2,580
Heating capacity
Min.
kW
1.2
Btu/h
4,100
kcal/h
1,030
Nom.
kW
3.4 (1)
Btu/h
11,600 (1)
kcal/h
2,920 (1)
Max.
kW
4.5
Btu/h
15,400
kcal/h
3,870
Power input
Cooling
Min.
kW
0.300
Nom.
kW
0.668 (1)
Max.
kW
0.860
Heating
Min.
kW
0.290
Nom.
kW
0.960 (1)
Max.
kW
1.490
2-5 Capacity and Power input
FVXS25F/RXS25L3
FVXS35F/RXS35L3
Summary of Contents for RXS-L3
Page 1: ...Split Air Conditioning Technical Data RXS L3...