Electrical data
3 - 1 Electrical Data
A
B
C
MCA MFA
RHz
RLA
kW
FLA
kW
FLA
50
220
MAX.
50
Hz
264V
2,30
0,24
0,19
50
230
2,20
0,23
0,18
50
240
2,10
0,22
0,17
50
220
MAX.
50
Hz
264V
2,82
0,24
0,19
50
230
2,70
0,23
0,18
50
240
2,59
0,22
0,17
50
220
MAX.
50
Hz
264V
2,93
50
230
2,80
50
240
2,68
50
220
MAX.
50
Hz
264V
2,61
50
230
2,50
50
240
2,40
50
220
MAX.
50
Hz
264V
4,29
50
230
4,10
50
240
3,93
50
220
2,60
50
230
2,50
50
240
2,30
OFM
IFM
FLA
kW
RHz
COMP
OFM
IFM
0,023
0,016
MIN.
50Hz
198V
FTXS25K3V1B
RXS25L3V1B
8
10
47
0,023
0,016
FTXS20K3V1B
RXS20L3V1B
8
10
35
MIN.
50Hz
198V
FVXS25FV1B
RXS25L3V1B
9,75
10
FLXS25BAVMB
RXS25L3V1B
9,75
10
50
0,023
0,23
0,048
0,05
MIN.
50Hz
198V
48
0,023
0,23
0,034
0,34
MIN.
50Hz
198V
2
0,031
0,2
0,034
0,3
MIN.
50Hz
198V
FFQ25C2VEB
RXS25L3V1B
MAX.
50Hz
264V
MIN.
50Hz
198V
9,75
10
FDXS25F2VEB
RXS25L3V1B
9,75
16
54
0,023
0,23
0,050
0,3
1
MCA
MFA
RLA
3
4
A
B
C
Voltage
range
Voltage
Hz
Outdoor
Indoor
Unit
combination
restrictions
Power
supply
Symbols
Minimum
Circuit
Ampere
(A)
Maximum
Fuse
Ampere
(A)
Rated
load
amps
[A]
Outdoor
fan
motor
Indoor
fan
motor
Full
Load
Ampere
(A)
Fan
motor
rated
output
[kW]
Notes
The
RLA
is
based
on
the
following
conditions.
Indoor
temperature
27°C
DB
/
19°C
WB
Outdoor
temperature
35°C
DB
Select
the
wire
size
according
to
the
MCA.
Use
a
circuit
breaker
instead
of
a
fuse.
Rated
operating
frequency
[Hz]
The
maximum
allowable
voltage
that
is
unbalanced
between
phases
is
2%.
RXS20
Ͳ
25L3
3D092002A
1
2
3
MCA MFA
RHz
RLA
kW
FLA
kW
FLA
OFM
IFM
FLA
kW
RHz
COMP
MCA
MFA
RLA
3
4
༃
༄
༅
1
2
㻜㻘㻞㻞
㻠㻘㻝
㻜㻘㻜㻟㻝
㻜㻘㻞
㻜㻘㻜㻟㻠
㻜㻘㻟
㻲㻺㻽㻟㻡㻭㻞㼂㻱㻮
㻾㼄㻿㻟㻡㻸㻟㼂㻝㻮
㻥㻜
㻡㻘㻡
㻜㻘㻜㻟㻡
㻲㻺㻽㻞㻡㻭㻞㼂㻱㻮
㻾㼄㻿㻞㻡㻸㻟㼂㻝㻮
㻡㻜
㻞㻞㻜㻙
㻞㻠㻜㼂
㻹㻭㼄㻚㻌㻡㻜㻴㼦㻌
㻞㻢㻠㼂
㻹㻵㻺㻚㻌㻡㻜㻴㼦㻌
㻝㻥㻤㼂
㻝㻞
㻝㻢
㻡㻠
COMP
OFM
IFM
Voltage
range
Voltage
Hz
Outdoor
Indoor
Unit
combination
restrictions
Power
supply
Symbols
Minimum
Circuit
Ampere
(A)
Maximum
Fuse
Ampere
(A)
Rated
load
amps
[A]
Outdoor
fan
motor
Indoor
fan
motor
Full
Load
Ampere
(A)
Fan
motor
rated
output
[kW]
Notes
The
RLA
is
based
on
the
following
conditions.
Indoor
temperature
27°C
DB
/
19°C
WB
Outdoor
temperature
35°C
DB
Select
the
wire
size
according
to
the
MCA.
Use
a
circuit
breaker
instead
of
a
fuse.
Rated
operating
frequency
[Hz]
The
maximum
allowable
voltage
that
is
unbalanced
between
phases
is
2%.
Compressor
RXS25
Ͳ
35L3
3D096315C