53
10.2
Electrical diagram
A
Earth connection exchanger
F
Fuse (3.15 A T)
P1
CH pump
B
Ignition hood
G
Gas block + ignition module
V
Fan
C
Boiler controller
I
Ignition/ionization pin
S1
Leaving water sensor
E
Earth connections
M
Mains electricity supply
S2
Return sensor
Connector X4
24V=
5 -
PWM control CH-pump. (5= PWM signal (red), E=earth)
6-7
On/off room thermostat
(0.1A-24Vdc)
and/or frost thermostat
8-9
Outdoor sensor
(12 kOhm / 25°C)
9-10
Tank sensor (remove through-connection)
11-12
OpenTherm room thermostat
(6-7 should be open)
Connector X2
230V
~
2-4
Mains supply 230 V (2 = L (brown), 4 = N (blue))
3-6
Electricity supply for fan (230 V, for RHOB42AAV1 only))
7-8
CH pump
(8 = L (brown), 7 = N (blue))
3-5-6
Three-way valve for external tank
(3 = L (brown), 5 = Switch (black), 6 = N (blue))
(e.g. EK3WV1AA)
Connector X5
Computer interface
10.3
NTC resistances
NTC 12k Ohm
T [°C]
R [ohm]
T [°C]
R [ohm]
T [°C]
R [ohm]
T [°C]
R [ohm]
-15
76020
15
18300
45
5522
75
1994
-10
58880
20
14770
50
4609
80
1717
-5
45950
25
12000
55
3863
85
1467
0
36130
30
9805
60
3253
90
1266
5
28600
35
8055
65
2752
95
1096
10
22800
40
6653
70
2337
100
952
Summary of Contents for ROTEX GW-20 H12
Page 1: ...ROTEX 4P374380 1D 88554801 02 2016 4P374380 1D 88554801 02 2016...
Page 29: ...30...
Page 81: ...30...
Page 133: ...30...
Page 185: ...30...
Page 237: ...30...
Page 290: ...30...
Page 342: ...30...
Page 395: ...31...
Page 421: ...57...
Page 422: ...58...
Page 423: ...59...
Page 424: ...ROTEX 008 1548799_00 88554803 05 2018 4P374380 1D 88554801 02 2016...