51
10
TECHNICAL SPECIFICATIONS
Unit category
B23 ; B33 ; C13; C33; C43; C53; C63; C83:C93
Initial gas pressure
G20 : 20 mbar; G25: 25 mbar; G31: 28-50 mbar
Suitable for gas
IT, ES, CZ : II2H3P
FR : II2Esi3P
DE
: II2ELL3P
BE : I2E(S)
PL
: II2E3P
Technical data
RHOB*AAV1H
12
18
42
CH
Nom. load upper value*
kW
3.9 – 13.1
6.2 – 20.8
8.6 – 47.1
Nom. load lower value*
kW
3.5 – 11.8
5.6 – 18.7
7.8 – 42.5
Nom. input at 80/60°C
kW
3.4 –11.5
5.4 –17.8
7.7 – 40.9
Nom. input at 50/30°C
kW
3.8 – 12.0
5.9 – 18.1
8.5 – 42.2
Max. CH water pressure
bar
3
Max. CH water temperature
°C
90
Other data
Gas consumption (G25)
m
3
/h
0.42 – 1.42
0.64 – 2.25
0.94 – 5.10
Gas consumption (G20)
m
3
/h
0.36 – 1.22
0.55 – 1.94
0.81 – 4.41
Gas consumption (G31)
m
3
/h
0.14 – 0.47
0.21 – 0.74
0.31 – 1.68
Pressure loss of the unit (CH)
mH
2
O
See par. 7.5
Max. Flue gas temperature DHW
°C
90
90
70
Mass.flow flue gas (max)
g/s
5,5
8,3
19,9
Available fan pressure
Pa
75
75
140
NOx class
6
6
6
NOx
mg/kWh
30
30
43
P1, at 30% of rated input (30/37)
kW
3,8
6,0
13,6
P4, Rated output (80/60)
kW
11,5
17,8
40,9
ɳ
1, Efficiency at P1
%
108,8
107,1
106,5
ɳ
4, Efficiency at P4
%
97,7
95,4
96,2
Electrical data
Mains voltage
V
230
230
230
Safety class
IP
IP44
(B23, B33 = IP20)
IP44
(B23, B33 = IP20)
IP44
(B23, B33 = IP20)
Absorbed power: full load
W
80
80
135
Absorbed power: standby
W
2
2
2
Installation measurements and weight
Height
mm
590
590
710
Width
mm
450
Depth
mm
240
Weight
kg
30
30
36
* The maximum CH power is set in the factory. For the set value see the parameter list.
Summary of Contents for ROTEX GW-20 H12
Page 1: ...ROTEX 4P374380 1D 88554801 02 2016 4P374380 1D 88554801 02 2016...
Page 29: ...30...
Page 81: ...30...
Page 133: ...30...
Page 185: ...30...
Page 237: ...30...
Page 290: ...30...
Page 342: ...30...
Page 395: ...31...
Page 421: ...57...
Page 422: ...58...
Page 423: ...59...
Page 424: ...ROTEX 008 1548799_00 88554803 05 2018 4P374380 1D 88554801 02 2016...