SiUS181305E
Indoor Unit
Printed Circuit Board Connector Wiring Diagram
18
3. Indoor Unit
3.1
CTXS07LVJU
Control PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than JA, JB, and JC.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S1
Connector for DC fan motor
2) S21
Connector for centralized control (HA)
3) S25
Connector for INTELLIGENT EYE sensor PCB
4) S32
Indoor heat exchanger thermistor
5) S41
Connector for swing motors
6) S46
Connector for display PCB
7) S47
Connector for signal receiver PCB
8) H1, H2, H3, FG
Connector for terminal board
9) JA
Address setting jumper
Refer to page 111 for detail.
10)JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
Refer to page 112 for detail.
11)LED A
LED for service monitor (green)
12)FU1 (F1U)
Fuse (3.15 A, 250 V)
13)V1
Varistor
V1
FU1
S1
S41
S21
S47
JB
JA
JC
S46
S25
LED A
S32
FG
H1
H2
H3
2P206687-4