Function of CTXS, FTXS, CDXS, FDXS Series
SiUS181305E
63
Function
7.2
Airflow Direction Control (CTXS/FTXS Series Only)
Power-Airflow
Dual Louvers
The large louver sends a large volume of air downward to the floor and provides an optimum
control in cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the louver retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
<Heating>
During heating operation, the large louver directs airflow downward to spread the warm air to the
entire room.
Wide-Angle Fins
The fins, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing
The following table explains the auto-swing process for cooling, dry, heating, and fan:
CTXS07LVJU
CTXS07JVJU, CTXS09/12HVJU
FTXS15/18/24LVJU
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling / Dry
Heating
Fan
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling
Dry
Heating
Fan
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling / Dry
Heating
Fan
15˚
45˚
35˚
55˚
(R13527)
30˚
70˚
30˚
65˚
(R11402)
5˚
80˚
30˚
65˚
(R11403)
45˚
45˚
(R11404)
10˚
40˚ 10˚
40˚
(R2814)
5˚
35˚
5˚
35˚
(R2815)
15˚
55˚
15˚
55˚
(R2813)
5˚
55˚
5˚
55˚
(R2816)
50˚
50˚
(R2817)
(R9303)
60˚
50˚
25˚
15˚
(R9304)
70˚
40˚ 75˚
30˚
(R9305)
75˚
15˚
25˚
70˚
(R9306)
45˚ 45˚