![background image](http://html1.mh-extra.com/html/daikin/rkn18nmvju/rkn18nmvju_service-manual_2459845014.webp)
Thermistor ASSY / Partition Plate
Si001556E
12
Removal Procedure
5. Thermistor ASSY / Partition Plate
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw of
the stop valve cover.
2
Slide the stop valve
cover downward and
remove it.
When reassembling, make
sure to fit the 3 hooks.
3
Release the outdoor
temperature thermistor
harness from the slit.
Stop valve
cover
(R21899)
Stop valve cover
(R21900)
Hook
Hook
(R21901)
Slit
Outdoor temperature
thermistor
(R21902)