![background image](http://html1.mh-extra.com/html/daikin/rkn18nmvju/rkn18nmvju_service-manual_2459845020.webp)
Electronic Expansion Valve Coil / Compressor
Si001556E
18
Removal Procedure
2
Remove the terminal
cover.
3
4
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
5
6
7
8
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts.
Lift up the compressor
and remove it.
Step
Procedure
Points
Terminal cover
(R21915)
Overload protector Protection bushing
U (red)
V (yellow)
W (blue)
(R21916)
Nut
Brazed part of the
suction side pipe
Brazed part of the
discharge side pipe
(R21917)