![background image](http://html1.mh-extra.com/html/daikin/rkn18nmvju/rkn18nmvju_service-manual_2459845011.webp)
Si001556E
Electrical Box
Removal Procedure
9
11
Disconnect the
connector [S40].
[S40]: overload protector
12
Disconnect the
connector [S30].
[S30]: compressor motor
13
Disconnect the
connector [S90] and
pull out the clamp.
[S90]: thermistors
14
Remove the screw and
remove the electrical
box.
Step
Procedure
Points
[S40]
(R21890)
[S30]
(R21891)
[S90]
Clamp
(R21892)
Electrical box