Removal Procedure
7
Remove the 2 screws
and remove the conduit
mounting plate.
When reassembling, be sure
to fit the 2 hooks on the
conduit mounting plate to the
right side panel.
8
Remove the 2 screws.
9
Disconnect the
connector [S20].
[S20]: electronic expansion
valve coil
10
Disconnect the 2
connectors from the
reactor.
When reassembling, you
can reconnect the 2
connectors for the reactor in
either way regardless of the
color.
Step
Procedure
Points
Conduit
mounting
plate
(R21886)
(R21918)
Hook
(R21887)
[S20]
(R21888)
Connector
Reactor