![background image](http://html1.mh-extra.com/html/daikin/rkm71pv16/rkm71pv16_service-manual-removal-procedure_2459841018.webp)
Electronic Expansion Valve
Si001408EA
16
Removal Procedure
2
3
4
Pull out the compressor
lead wires.
Remove the overload
protector.
Remove the protection
bushing.
5
Pull out the electronic
expansion valve coil.
6
7
Remove the sheets of
putty.
Heat up the 2 brazed
parts and remove the
electronic expansion
valve.
Step
Procedure
Points
Overload
protector
Protection bushing
V (yellow)
U (red)
W (blue)
(R20344)
Electronic
expansion
valve coil
(R20345)
Brazed part
Brazed part
Putty
Electronic
expansion
valve
(R20346)