![background image](http://html1.mh-extra.com/html/daikin/rkm71pv16/rkm71pv16_service-manual-removal-procedure_2459841007.webp)
Si001408EA
Outdoor Fan / Fan Motor
Removal Procedure
5
4
Release the fan motor
lead wire from the hook
of the outdoor heat
exchanger.
5
Remove the nut and
remove the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
6
7
8
Remove the 2 screws
of the fan motor fixing
frame.
Pull up the fan motor
fixing frame to unfasten
the 2 hooks at the
bottom.
Remove the fan motor
fixing frame.
When reassembling, fit the 2
lower hooks into the bottom
frame.
Step
Procedure
Points
Hook
(R20311)
Nut
Outdoor fan
(R20312)
10 mm
(0.39 inch)
(R18954)
(R20313)
(R20314)