![background image](http://html1.mh-extra.com/html/daikin/rkm18pvmk/rkm18pvmk_removal-procedure_2459835011.webp)
Si001559E
Electrical Box
Removal Procedure
9
4
Disconnect the
connector [S80] and
pull out the clamp.
[S80]: four way valve coil
The cooling only models
have no harness for [S80].
5
Disconnect the relay
connector for
compressor and pull out
the clamp.
6
Disconnect the
connector [S40] and
pull out the clamp.
[S40]: overload protector
Step
Procedure
Points
[S80]
Clamp
(R22216)
Clamp
Relay connector
(R22217)
[S40]
Clamp
(R22218)