![background image](http://html1.mh-extra.com/html/daikin/rkm18pvmk/rkm18pvmk_removal-procedure_2459835008.webp)
Outdoor Fan / Fan Motor
Si001559E
6
Removal Procedure
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the electrical
box cover.
2
Disconnect the
connector [S70] and
release the fan motor
lead wire from the slit.
[S70]: fan motor
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
3
Remove the nut and
remove the outdoor fan.
Nut size : M8
When reassembling, align
the
mark of the fan rotor
with the D-cut section of the
motor shaft.
Electrical box cover
(R22208)
Fan motor lead wire
[S70]
Slit
(R22209)
Lead wire
Outdoor fan
(R3249)
Outdoor fan
Nut
D-cut
(R22210)
13 mm
(0.51 inch)
(R18965)