![background image](http://html1.mh-extra.com/html/daikin/rkm18pvmk/rkm18pvmk_removal-procedure_2459835010.webp)
Electrical Box
Si001559E
8
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 3 screws
and remove the wire
fixture.
2
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and
power supply wire.
3
Disconnect the
connector [S20] and
pull out the clamp.
[S20]: electronic expansion
valve coil
Wire fixture
(R22213)
Connecting wire
Terminal board
Power supply wire
(R22214)
[S20]
Clamp
(R22215)