![background image](http://html1.mh-extra.com/html/daikin/rkm18pvmk/rkm18pvmk_removal-procedure_2459835023.webp)
Si001559E
Compressor
Removal Procedure
21
2
3
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
4
5
6
7
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts.
Lift up the compressor
and remove it.
Step
Procedure
Points
U (red)
Protection bushing
V (yellow)
W (blue)
Overload
protector
(R22244)
Compressor
Nut
Brazed part of the
discharge side pipe
Brazed part of the
suction side pipe
(R22246)