3 Operation

Operation manual

5

RGSQH10S18AA9W
ROTEX HPU ground
4P353880-1A – 2015.10

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

3.4.3

Sch reheat mode

In sch reheat mode (   ), the domestic hot water control is
the  same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

DHW tank temperature

t

Time

60°C

Storage comfort

50°C

Storage eco

45°C

Reheat

35°C

Reheat tank temperature – hysteresis value

3.4.4

Using the DHW tank temperature home
page

Typical DHW tank temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  The  examples  in  the  illustrations
below are in DHW tank mode = Scheduled.

User profile = Basic

User profile = Detailed

15:20

60°C

Storage comfort

Tank

Mon

15:20

60°C

00:00

Mon

Tue

Tank

Storage comfort

To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)

1

Go  to  [7.4.3.3]: 

  >  User  settings  >  Preset  values  >  Tank

temperature > Reheat.

Result: 

You can read out the desired reheat temperature.

2

Press 

 or 

 to adjust.

To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)

1

Go to the DHW tank temperature home page (Tank).

Result: 

60°C

 is displayed.

2

Press 

 or 

 to overrule. 

Note: 

If the desired temperature is

weather dependent, you cannot change it on the home page.

3.4.5

Using the DHW tank booster mode

To activate the DHW tank booster mode (user profile = Basic)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (user profile = Detailed)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

3.5

Advanced usage

3.5.1

About changing the user permission level

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ End user (= default)

▪ Adv. end user: You can read out more information.

To set the user permission level to Advanced end user

1

Go to the main menu or any of its submenus: 

.

2

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu title.
The  user  permission  level  will  stay  in  Adv.  end  user  until  set
otherwise.

To set the user permission level to End user

1

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  End  user.  The  user

interface will return to the default home screen.

3.6

Schedules: Example

INFORMATION

The procedures to program other schedules are similar.

In this example:

▪ Room temperature schedule in heating mode

▪ Monday = Tuesday = Wednesday = Thursday = Friday

▪ Saturday = Sunday

To program the schedule

1

Go  to  [7.3.1.1]: 

  >  User  settings  >  Set  schedules  >  Room

temp. > Set heating schedule.

2

Select Empty and press 

.

3

Program the schedule for Monday. See below for more details.

4

Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.

5

Program the schedule for Saturday.

6

Copy from Saturday to Sunday.

7

Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.

To program the schedule for Monday

1

Use 

 and 

 to select Monday.

2

Press 

 to enter the schedule for Monday.

3

Program the schedule for Monday:

▪ Use 

 and 

 to select an entry.

▪ Use 

 and 

 to change the value of an entry.

Summary of Contents for RGSQH10S18AA9W

Page 1: ...Operation manual ROTEX HPU ground English Operation manual ROTEX HPU ground RGSQH10S18AA9W...

Page 2: ...the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings...

Page 3: ...menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the...

Page 4: ...temperature To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode wil...

Page 5: ...3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 seconds To activate the DHW tank...

Page 6: ...o save the schedule 1 Press select Save schedule and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules...

Page 7: ...unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT...