background image

Table of Contents

Operation manual

2

RGSQH10S18AA9W

ROTEX HPU ground

4P353880-1A – 2015.10

Table of Contents

1 About this document

2

2 About the system

2

2.1

Components in a typical system layout .....................................

2

3 Operation

3

3.1

Overview: Operation..................................................................

3

3.2

The user interface at a glance...................................................

3

3.2.1

Buttons........................................................................

3

3.2.2

Status icons ................................................................

3

3.3

Space heating control................................................................

4

3.3.1

Setting the space operation mode ..............................

4

3.3.2

Room thermostat control - Using the room
temperature home page..............................................

4

3.3.3

Room thermostat control - Using the leaving water
temperature home pages............................................

4

3.4

Domestic hot water control ........................................................

4

3.4.1

Reheat mode ..............................................................

4

3.4.2

Scheduled mode .........................................................

4

3.4.3

Sch reheat mode...........................................

5

3.4.4

Using the DHW tank temperature home page ............

5

3.4.5

Using the DHW tank booster mode ............................

5

3.5

Advanced usage........................................................................

5

3.5.1

About changing the user permission level ..................

5

3.6

Schedules: Example..................................................................

5

To select which schedule you currently want to use...

6

3.7

Menu structure: Overview user settings ....................................

7

3.8

Installer settings: Tables to be filled in by installer ....................

8

3.8.1

Quick wizard ...............................................................

8

3.8.2

Space heating control .................................................

8

3.8.3

Domestic hot water control [A.4] .................................

8

3.8.4

Contact/helpdesk number [6.3.2] ................................

8

4 Energy saving tips

8

5 Maintenance and service

8

5.1

Overview: Maintenance and service .........................................

8

5.2

To find the contact/helpdesk number ........................................

9

6 Troubleshooting

9

6.1

Symptom: You are feeling too cold (hot) in your living room.....

9

6.2

Symptom: The water at the tap is too cold ................................

9

6.3

Symptom: Heat pump failure .....................................................

9

7 Glossary

9

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format: Digital files on the ROTEX website.

Latest revisions of the supplied documentation may be available on
the regional ROTEX website or via your installer.

The original documentation is written in English. All other languages
are translations.

Available screens

Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.

Breadcrumbs

1

20.0°C >
18.0°C >

7.4.1.1

Room temperature

Comfort (heating)
Eco (heating)

Select

Scroll

Breadcrumbs help you to locate where you are in the menu structure
of  the  user  interface.  This  document  also  mentions  these
breadcrumbs.

Example: 

Go  to  [7.4.1.1]: 

  >  User  settings  >  Preset  values  >

Room temperature > Comfort (heating)

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Produce domestic hot water

2.1

Components in a typical system
layout

d

a

b

c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Brine loop

Summary of Contents for RGSQH10S18AA9W

Page 1: ...Operation manual ROTEX HPU ground English Operation manual ROTEX HPU ground RGSQH10S18AA9W...

Page 2: ...the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings...

Page 3: ...menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the...

Page 4: ...temperature To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode wil...

Page 5: ...3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 seconds To activate the DHW tank...

Page 6: ...o save the schedule 1 Press select Save schedule and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules...

Page 7: ...unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT...

Page 8: ...Maximum setpoint 60 C 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NE...

Page 9: ...DHW tank booster mode However this consumes extra energy If you can wait overrule increase the active or next scheduled desired temperature so that more hot water will be produced exceptionally If the...

Page 10: ......

Page 11: ......

Page 12: ...ffen Tel 33 0 3 89 21 74 70 Fax 33 0 3 89 21 74 74 e mail i nfo r otex fr www r otex fr DAIKIN AIRCONDITIONING BELGIUM NV A v e n u e F r a n k l i n 1 B B 1 3 0 0 W a v r e Tel 32 0 10 23 72 23 Fax 3...

Reviews: