3 Operation

Operation manual

4

RGSQH10S18AA9W

ROTEX HPU ground

4P353880-1A – 2015.10

Icon

Description

An external heat source is active. 

Example: 

Gas

burner.

The disinfection mode is active.

A malfunction occured. Press 

 to display more

information about the malfunction.

Weather-dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

Emergency operation is active.

INFORMATION

Quiet mode is NOT applicable for this unit.

3.3

Space heating control

3.3.1

Setting the space operation mode

About space operation modes

The heat pump is a heating only model. The system can heat up a
space, but NOT cool down a space.

3.3.2

Room thermostat control - Using the
room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to
Configuring  user  profile  and  home  pages  in  the  user  reference
guide.

User profile = Basic

User profile = Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room
temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature
schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset
value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

To set the overrule period

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [7.2]: 

 > User settings > Temperature lock.

2

Select a value and press 

:

▪ Permanent
▪ hours (2, 4, 6, 8)

3.3.3

Room thermostat control - Using the
leaving water temperature home pages

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.

Example: 

Underfloor heating is designed for lower leaving

water  temperature  than  radiators  and  heat  pump
convectors  and/or  fan  coil  units.  You  only  have  to  adjust
leaving water temperature settings in case of problems.

For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  ( ),the  DHW  tank  continuously  heats  up  to  the
temperature  shown  on  the  DHW  tank  temperature  home  page
(example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

DHW tank temperature

t

Time

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating  function  is
regularly interrupted.

3.4.2

Scheduled mode

In  scheduled  mode  ( ),  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because the space heating demand is
lower.

Example: 

Summary of Contents for RGSQH10S18AA9W

Page 1: ...Operation manual ROTEX HPU ground English Operation manual ROTEX HPU ground RGSQH10S18AA9W...

Page 2: ...the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings...

Page 3: ...menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the...

Page 4: ...temperature To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode wil...

Page 5: ...3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 seconds To activate the DHW tank...

Page 6: ...o save the schedule 1 Press select Save schedule and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules...

Page 7: ...unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT...

Page 8: ...Maximum setpoint 60 C 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NE...

Page 9: ...DHW tank booster mode However this consumes extra energy If you can wait overrule increase the active or next scheduled desired temperature so that more hot water will be produced exceptionally If the...

Page 10: ......

Page 11: ......

Page 12: ...ffen Tel 33 0 3 89 21 74 70 Fax 33 0 3 89 21 74 74 e mail i nfo r otex fr www r otex fr DAIKIN AIRCONDITIONING BELGIUM NV A v e n u e F r a n k l i n 1 B B 1 3 0 0 W a v r e Tel 32 0 10 23 72 23 Fax 3...

Reviews: