Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the User's Manual carefully before using this product. The User's Manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of July 2013 but subject to change without notice.

Si01-752

07/2013 AK.B

Summary of Contents for RE25JV1

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 5 kW Class Outdoor Unit Non Inverter Pair Type Si01 752...

Page 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only RE25JV1 RE35JV1...

Page 3: ...els 2 2 Removal of Bellmouth 4 3 Removal of Electrical Components ASSY 5 4 Removal of Outdoor Fan Fan Motor 6 5 Removal of Sound Blanket 8 6 Removal of Partition Plate 9 7 Removal of Compressor 10 Not...

Page 4: ...Procedure Points 1 Remove the screw and remove the stop valve cover As the stop valve cover has 3 hooks slide the cover downward to remove 2 The top panel and the front panel are constructed in a mon...

Page 5: ...hen remove it forward The left side plate and the bellmouth can be removed all at once When restoring the panel ASSY move it horizontally and get it down for the easy work 5 Remove the screw and remov...

Page 6: ...minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 The bellmouth is attached with 2 screws and 4 hooks 2 Remove the 2 screws and slide the bellmout...

Page 7: ...turning off all power supplies before disassembling work Step Procedure Points 1 Remove the drip proof plate 1 Remove the 3 screws of the drip proof plate 2 Remove the drip proof plate 2 Remove the el...

Page 8: ...rom the magnetic contactor Nut size M6 When reassembling align the mark of the outdoor fan with the D cut section of the motor shaft The fan motor should be restored so that the mark z will be at uppe...

Page 9: ...Si01 752 Removal of Outdoor Fan Fan Motor Removal Procedure 7 5 Remove the fan motor Step Procedure Points R12799...

Page 10: ...rews of the right side panel 2 Lift up and remove the right side panel When reassembling fit the 3 hooks 2 Remove the sound blanket Since the piping ports are torn easily remove the sound blanket care...

Page 11: ...all power supplies before disassembling work Step Procedure Points 1 Disengage the compressor lead wires from the wire clip 2 Remove the 2 screws of the partition plate 3 Pull and remove the partitio...

Page 12: ...fire immediately Caution From the viewpoint of global environment protection do not discharge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoratio...

Page 13: ...he pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazing flame cannot influence peripheries Be careful so as...

Page 14: ...Revision History Month Year Version Revised contents 07 2013 Si01 752 First edition...

Page 15: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...