background image

Removal of Compressor

Si01-752

10

Removal Procedure

7. Removal of Compressor

Procedure

Warning

Be sure to wait 10 minutes or more after turning off all power supplies 
before disassembling work.

Step

Procedure

Points

„

Before working, make 
sure that the refrigerant is 
empty in the circuit.

„

Be sure to apply nitrogen 
replacement when 
heating up the brazed 
part.

Warning

Be careful not to get yourself 
burnt with the pipes and other 
parts that are heated by the 
gas brazing machine.

Warning

If the refrigerant gas leaks 
during work, ventilate the 
room. (If the refrigerant gas is 
exposed to flames, toxic gas 
may be generated.)

Warning

Since it may happen that the 
refrigerant oil in the 
compressor catches fire, 
prepare wet cloth so as to 
extinguish fire immediately.

Caution

From the viewpoint of global 
environment protection, do 
not discharge the refrigerant 
gas in the atmosphere. Make 
sure to collect all the 
refrigerant gas.

Cautions for restoration

1. Restore the piping by non-

oxidation brazing. 

2. It is required to prevent the 

carbonization of the oil inside 
the four way valve and the 
deterioration of the gaskets 
affected by heat. (Keep 
below 120°C.) For the sake 
of this, wrap the four way 
valve with wet cloth and 
provide water so that the 
cloth does not dry.

In case of difficulty with gas 
brazing machine 

1. Disconnect the brazed part 

where is easy to disconnect 
and restore.

2. Cut pipes on the main unit 

with a tube cutter in order to 
make it easy to disconnect.

1

Remove the terminal 
cover and the partition 
plate.

2

Disconnect the 
compressor lead wires.

3

Remove the 3 nuts of 
the compressor.

Lead wires for 
the compressor

(R12803)

Partition 
plate

Terminal cover

Red

Blue

Yellow

(R12802)

Summary of Contents for RE25JV1

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 5 kW Class Outdoor Unit Non Inverter Pair Type Si01 752...

Page 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only RE25JV1 RE35JV1...

Page 3: ...els 2 2 Removal of Bellmouth 4 3 Removal of Electrical Components ASSY 5 4 Removal of Outdoor Fan Fan Motor 6 5 Removal of Sound Blanket 8 6 Removal of Partition Plate 9 7 Removal of Compressor 10 Not...

Page 4: ...Procedure Points 1 Remove the screw and remove the stop valve cover As the stop valve cover has 3 hooks slide the cover downward to remove 2 The top panel and the front panel are constructed in a mon...

Page 5: ...hen remove it forward The left side plate and the bellmouth can be removed all at once When restoring the panel ASSY move it horizontally and get it down for the easy work 5 Remove the screw and remov...

Page 6: ...minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 The bellmouth is attached with 2 screws and 4 hooks 2 Remove the 2 screws and slide the bellmout...

Page 7: ...turning off all power supplies before disassembling work Step Procedure Points 1 Remove the drip proof plate 1 Remove the 3 screws of the drip proof plate 2 Remove the drip proof plate 2 Remove the el...

Page 8: ...rom the magnetic contactor Nut size M6 When reassembling align the mark of the outdoor fan with the D cut section of the motor shaft The fan motor should be restored so that the mark z will be at uppe...

Page 9: ...Si01 752 Removal of Outdoor Fan Fan Motor Removal Procedure 7 5 Remove the fan motor Step Procedure Points R12799...

Page 10: ...rews of the right side panel 2 Lift up and remove the right side panel When reassembling fit the 3 hooks 2 Remove the sound blanket Since the piping ports are torn easily remove the sound blanket care...

Page 11: ...all power supplies before disassembling work Step Procedure Points 1 Disengage the compressor lead wires from the wire clip 2 Remove the 2 screws of the partition plate 3 Pull and remove the partitio...

Page 12: ...fire immediately Caution From the viewpoint of global environment protection do not discharge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoratio...

Page 13: ...he pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazing flame cannot influence peripheries Be careful so as...

Page 14: ...Revision History Month Year Version Revised contents 07 2013 Si01 752 First edition...

Page 15: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...