![background image](http://html1.mh-extra.com/html/daikin/re25jv1/re25jv1_removal-procedure_2459793008.webp)
Removal of Outdoor Fan / Fan Motor
Si01-752
6
Removal Procedure
4. Removal of Outdoor Fan / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Disconnect the 3
terminals of the fan
motor lead wire.
(2 from the fan motor
capacitor, 1 from the
magnetic contactor)
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
The fan motor should be
restored so that the mark
z
will be at upper side.
2
Remove the nut and
remove the outdoor fan.
3
4
Open the 2 hooks and
release the fan motor
lead wire.
Remove the 2 screws
of the fan motor.
Fan motor
lead wire: black
Fan motor capacitor
Red
White
Black
Fan motor
lead wire
Magnetic
contactor
A
View from
A
(R12890)
10 mm
(R12236)
(R1861)
T
Mark
(R12797)
D cut
z
Mark
(R12798)
Hook