3. Removal of Electrical Components ASSY
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the drip proof
plate.
1
Remove the 3 screws
of the drip proof plate.
2
Remove the drip proof
plate.
2. Remove the electrical
components ASSY.
1
Disconnect all the
harnesses.
2
Remove the 2 screws
of electrical
components ASSY.
3
Remove the electrical
components ASSY.
(R1857)
(R1858)