![background image](http://html1.mh-extra.com/html/daikin/multi-r32-split-series/multi-r32-split-series_installers-reference-manual_4701102068.webp)
15
|
Troubleshooting
Installer reference guide
68
4MWXM-A9
R32 Split series
4P708645-1 – 2022.09
a
a
Location of LED
Symbol
LED is...
ON
OFF
Flashing
Red LED
(a)
Diagnosis
1
2
3
4
5
Normal.
▪
Check the indoor unit.
High-pressure protector worked or freeze-up in operating
unit, or stand-by unit.
Overload relay worked or high discharge pipe
temperature.
(b)
Faulty compressor start.
Input over-current.
Thermistor or CT abnormality.
(b)
High temperature switch box.
High temperature at inverter circuit heat sink.
Output over-current.
(b)
Refrigerant shortage.
(b)
Low voltage to main circuit or over voltage to main circuit.
Reversing solenoid valve switching failure or high-pressure
switching failure.
(b)
Faulty outdoor unit PCB.
Fan motor fault.
Wiring error
▪
Check wiring.
(a)
The number of LEDs displayed depends on the number of rooms.
(b)
Diagnosis may not apply to some cases. For more details, refer to the service manual.
Green LED-A
Diagnosis
Normal.
▪
Check the indoor unit.
Turn the power OFF and back ON, and check the LED
within approximately 3 minutes. If the LED is ON again,
the outdoor unit PCB is faulty.
Power supply fault.
(a)
Summary of Contents for Multi+ R32 Split Series
Page 1: ...Installer reference guide R32 Split series 4MWXM52A2V1B9...
Page 31: ...6 Unit installation Installer reference guide 31 4MWXM A9 R32 Split series 4P708645 1 2022 09...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ...4P708645 1 2022 09 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...