9
|
Electrical installation
Installer reference guide
48
4MWXM-A9
R32 Split series
4P708645-1 – 2022.09
9 Electrical installation
In this chapter
9.1 About connecting the electrical wiring
Before connecting the electrical wiring
Make sure the refrigerant piping is connected and checked.
Typical workflow
Connecting the electrical wiring typically consists of the following stages:
1
Making sure the power supply system complies with the electrical
specifications of the heat pump.
2
Connecting the electrical wiring to the outdoor unit.
3
Connecting the electrical wiring to the indoor unit.
4
Connecting the main power supply of the indoor unit.
5
Connecting the main power supply of the gas boiler.
6
Connecting the communication cable between the gas boiler and the indoor
unit.
7
Connecting the user interface.
8
Connecting the shut-off valves.
9
Connecting the domestic hot water tank.
10
Connecting the alarm output.
11
Connecting the space heating ON/OFF output.
12
Connecting the safety thermostat.
9.1.1 Precautions when connecting the electrical wiring
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF ELECTROCUTION
All electrical parts (including thermistors) are powered by the power supply. Do NOT
touch them with bare hands.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10 minutes, and measure the voltage at
the terminals of main circuit capacitors or electrical components before servicing.
The voltage MUST be less than 50 V DC before you can touch electrical components.
For the location of the terminals, see the wiring diagram.
Summary of Contents for Multi+ R32 Split Series
Page 1: ...Installer reference guide R32 Split series 4MWXM52A2V1B9...
Page 31: ...6 Unit installation Installer reference guide 31 4MWXM A9 R32 Split series 4P708645 1 2022 09...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ...4P708645 1 2022 09 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...