![background image](http://html2.mh-extra.com/html/daikin/inverter-ftxl20g2v1b/inverter-ftxl20g2v1b_service-manual_3625026245.webp)
Outdoor Unit - RXL25G2V1B
SiENBE04-925_A
230
Removal Procedure
4.6
Removal of Outdoor Fan / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the outdoor fan.
The screw has reverse
winding.
Nut size: M6
1
Remove the washer
fitted nut of the outdoor
fan.
2
Remove the outdoor
fan.
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
2. Remove the fan motor.
1
Disconnect the
connector for the fan
motor [S70].
(R8181)
10 mm
(R12236)
(R8182)
D-cut
(R8183)
(R8184)
[S70]
SIENBE04-925_A_FRONT.pdf 245
24/02/2011 13:54:15