Removal Procedure
3. Remove the fan motor.
The screw has reverse
winding.
Nut size: M6
1
Remove the washer-
fitted nut of the outdoor
fan.
2
Remove the outdoor
fan.
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
3
Release the outdoor
temperature thermistor.
Step
Procedure
Points
(R11827)
Outdoor fan
10 mm
(R12236)
(R12308)
D-cut
(R12289)
Outdoor temperature
thermistor