• In the upper space (including the back of the ceiling) of 

the indoor unit where there is no possible dripping of 
water from the refrigerant pipe, drain pipe, water pipe, 
etc.

• If supporting structural members are not strong enough 

to take the unit’s weight, the unit could fall out of place 
and cause serious injury.

• Where the false ceiling is not noticeably on an incline.
• Where there is no risk of flammable gas leakage.
• Where sufficient clearance for maintenance and service 

can be ensured.

• Where piping between indoor and outdoor units is possi-

ble within the allowable limit. (Refer to the installation 
manual for the outdoor unit.)

CAUTION

• Install the indoor and outdoor units, power supply wiring and 

connecting wires at least 1 meter away from televisions or 
radios in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter may 
not be sufficient enough to eliminate the noise.)

• Install this unit where the height of bottom panel is more 

than 2.5 m so that the user cannot easily touch.

[ PRECAUTION ]

If installing the wireless kit in a room with electronic fluores-
cent lighting (inverter or rapid start type), the remote con-
troller’s transmission distance may be shortened. Indoor 
units should be installed as far away from fluorescent light-
ing as possible. 

(2) Use suspension bolts for installation. Check whether 

the ceiling is strong enough to support the weight of 
the unit or not. If there is a risk, reinforce the ceiling 
before installing the unit.

(Installation pitch is marked on the paper pattern for installation. 
Refer to it to check for points requiring reinforcing.)

4.

PREPARATIONS BEFORE INSTALLA-

TION

(1) Relation of ceiling opening to unit and suspension bolt 

position.

• For standard installation (air inlet on the bottom side), 

choose one of the below two means of installation.
Note: For other than standard installation, contact your 

Daikin dealer for details.

Maintenance
space

F

or installation 

in high places

300 mm
or more

2500 mm

or more

Drain pipe

Liquid pipe

Power supply 
wiring port

Maintenance drain hose

Transmission
wiring port

Gas pipe

Model

A (mm)

B (mm)

FXSN20 · 25 · 32AV1

550

600

FXSN40 · 50AV1

700

750

FXSN63 · 100AV1

1400

1450

For mounting air inlet panel with canvas connection

Model

A (mm)

FXSN20 · 25 · 32AV1

610

FXSN40 · 50AV1

760

FXSN63 · 100AV1

1460

B

A

Pipe

Suspension
bolt pitch

Indoor unit

800

Suspension bolt (× 4)

145

Suspension bolt pitch 

630

(length : mm)

Air inlet panel

160

425

or more

(Optional accessory)

460

180

(160

-

300)

Ceiling
opening

 

Ceiling
surface

A

(Ceiling opening)

Indoor unit
(Back side)

Canvas
connection
for air inlet 
panel

(Optional accessory)

(length : mm)

01_EN_3P233622-5F.fm  Page 4  Thursday, December 18, 2008  4:21 PM

Summary of Contents for FXSN100AV1

Page 1: ...ONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE BEWAAR DEZE HAN DLEINDING WAAR U HEM KU...

Page 2: ...urata Manager Quality Control Department 1st of October 2008 DAIKIN TCF 024C19 07 2008 T V Rheinland EPS B V 0510260101 RXYN10AY1 FXSN20AV1 FXSN25AV1 FXSN32AV1 FXSN40AV1 FXSN50AV1 FXSN63AV1 FXSN100AV1...

Page 3: ...Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Failure to do so during installation work may result in the unit falling and causing accidents...

Page 4: ...st be retained in your custody until the installation work is completed Do not discard them Decide upon a line of transport Leave the unit inside its packaging while moving until reach ing the install...

Page 5: ...ual Installation manual Sealing material Small 35 150 Quantity 6 pcs Shape Model Min height above ceiling Air inlet panel Canvas connection for air inlet panel Color White FXSN20 25 32AV1 350mm or mor...

Page 6: ...shortened Indoor units should be installed as far away from fluorescent light ing as possible 2 Use suspension bolts for installation Check whether the ceiling is strong enough to support the weight...

Page 7: ...the screws as shown in the drawing The paper pattern for installation is marked for 3 types of ceil ing openings Read the notations on the paper pattern care fully when installing 6 REFRIGERANT PIPIN...

Page 8: ...to insulate any field piping all the way to the piping connection inside the unit Any exposed piping may cause condensation or burns if touched CAUTION CAUTION TO BE TAKEN WHEN BRAZING REFRIGER ANT PI...

Page 9: ...rainage flow during COOL running explained under TEST OPERATION WHEN ELECTRIC WIRING WORK IS NOT FINISHED Remove the electric parts box lid connect a power supply and remote controller to the terminal...

Page 10: ...wn below Be sure to adhere it to avoid water from outside unit CAUTION When clamping the wires be sure no pressure is applied to the wire connections by using the included clamping material to make ap...

Page 11: ...e of the sort could damage the entire system 7 Use only specified wire and tightly connect wires to termi nals Be careful wires do not place external stress on termi nals Keep wiring in neat order and...

Page 12: ...llowing table explains FORCED OFF and ON OFF OPERATIONS in response to Input A 3 How to select FORCED OFF and ON OFF OPERATION Turn the power on and then use the remote controller to select operation...

Page 13: ...11 TEST OPERATION Refer to the installation manual of the outdoor unit The operation lamp of the remote controller will flash when an malfunction occurs Check the malfunction code on the liquid cryst...

Page 14: ...0901 FS HT 3P233622 5F EM08A072B...

Reviews: