• Do not install the air conditioner in the following locations: 

1.

Where there is a high concentration of mineral oil spray 
or vapour (e.g. a kitchen).
Plastic parts will deteriorate, parts may fall off and water 
leakage could result.

2.

Where corrosive gas, such as sulphurous acid gas, is 
produced. 
Corroding of copper pipes or soldered parts may result 
in refrigerant leakage. 

3.

Near machinery emitting electromagnetic radiation. 
Electromagnetic radiation may disturb the operation of 
the control system and result in a malfunction of the unit.

4.

Where flammable gas may leak, where there is carbon 
fibre or ignitable dust suspensions in the air, or where 
volatile flammables such as paint thinner or gasoline 
are handled.
Operating the unit in such conditions may result in fire.

2.

BEFORE INSTALLATION

2-1

About This Product

• This product uses R744 (CO

2

) refrigerant. The utmost atten-

tion is required to handle R744 refrigerant, and strict mea-
sures must be taken to keep impurities (including mineral oil 
and other types of oil as well as moisture) out of the system. 
Be sure to follow the instructions in “6. REFRIGERANT PIP-
ING WORK”.

• The design pressure is 12.3 MPa (4.0 MPa for R410A). 

Therefore, the following conventional parts cannot be used.
• Connection pipes

............. Thick-walled pipes are required. Refer to 

“6. REFRIGERANT PIPING WORK” for the 
specifications of the pipes.

• Flare nut connections

............. Unavailable. Perform brazing connections.

• Pipe brazing joints

Pipes with a maximum diameter of 12.7 mm

............. Make brazing connections with sleeve flare 

processing.

Pipes with a diameter of 15.9 mm

............. Use sockets sold as optional accessories.

• Elbows

............. Use products sold as optional accessories.

• Installation instruments that must withstand high pres-

sures, such as charge hoses and pressure gauges

............. Use pressure-resistant instruments that with-

stand a minimum pressure of 12.3 MPa.

• The outdoor unit and BEV unit are R744-dedicated units. 

Check the model names of connectable indoor units with 
datasheets including catalogs. The air conditioner will not 
operate normally if other indoor unit models are connected.

When moving the unit while removing it from the carton 
box, be sure to lift it by holding on to the four lifting lugs 
without exerting any pressure on other parts, especially, 
the refrigerant piping, drain piping, and other resin parts.

• The accessories needed for installation must be retained in 

your custody until the installation work is completed. Do not 
discard them!

• Decide upon a line of transport.
• Leave the unit inside its packaging while moving, until reach-

ing the installation site. Where unpacking is unavoidable, use 
a sling of soft material or protective plates together with a 
rope when lifting, to avoid damage or scratches to the unit.

• When moving the unit at or after opening, hold the unit by the 

hanger brackets (×4). Do not apply force to the refrigerant 
piping, drain piping or plastic parts.

• When selecting installation site, refer to the paper pattern.

• For the installation of an outdoor unit, refer to the installation 

manual attached to the outdoor unit.

• Do not install or operate the unit in rooms mentioned below.

Laden with mineral oil, or filled with oil vapor or spray 
like in kitchens. (Plastic parts may deteriorate which 
could eventually cause the unit to fall out of place, or 
could lead to leaks.)

Where corrosive gas like sulfurous gas exists. (Cop-
per tubing and brazed spots may corrode, which 
could eventually lead to refrigerant leaks.)

Where exposed to combustible gases and where vol-
atile flammable gas like thinner or gasoline is used. 
(Gas in the vicinity of the unit could ignite.)

Where machines can generate electromagnetic 
waves. (Control system may malfunction.)

Where the air contains high levels of salt such as that 
near the ocean and where voltage fluctuates greatly 
such as that in factories.  Also in vehicles or vessels.

• This unit, both indoor and outdoor, is suitable for installation in 

a commercial and light industrial environment.
If installed as a household appliance it could cause electro-
magnetic interference.

2-2

PRECAUTIONS

• Be sure to read this manual before installing the indoor unit.
• Entrust installation to the place of purchase or a qualified ser-

viceman. Improper installation could lead to leaks and, in 
worse cases, electric shock of fire.

• Use only parts provided with the unit or parts satisfying 

required specifications. Unspecified parts could cause the 
unit to fall out of place, or could lead to leaks and, in worse 
cases, electric shock or fire.

2-3

ACCESSORIES

Check the following accessories are included with your unit.

Name

Metal clamp

Paper pattern for 

installation

Quantity

1 pc.

1 pc.

Shape

Name

Drain hose

Insulation for fitting

Quantity

1 pc.

1 each.

Shape

for gas pipe

for liquid pipe

Name

Sealing pad

Screws for duct flanges

Quantity

1 each.

1 set

Shape

Large

mid

Name

Washer for hanging 

bracket

Clamp

Quantity

8 pcs.

6 pcs.

Shape

FXSN20 . 25 . 32AV1

FXSN40 . 50AV1

FXSN63 . 100AV1

6

8

16

01_EN_3P233622-5F.fm  Page 2  Thursday, December 18, 2008  4:21 PM

Summary of Contents for FXSN100AV1

Page 1: ...ONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE BEWAAR DEZE HAN DLEINDING WAAR U HEM KU...

Page 2: ...urata Manager Quality Control Department 1st of October 2008 DAIKIN TCF 024C19 07 2008 T V Rheinland EPS B V 0510260101 RXYN10AY1 FXSN20AV1 FXSN25AV1 FXSN32AV1 FXSN40AV1 FXSN50AV1 FXSN63AV1 FXSN100AV1...

Page 3: ...Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Failure to do so during installation work may result in the unit falling and causing accidents...

Page 4: ...st be retained in your custody until the installation work is completed Do not discard them Decide upon a line of transport Leave the unit inside its packaging while moving until reach ing the install...

Page 5: ...ual Installation manual Sealing material Small 35 150 Quantity 6 pcs Shape Model Min height above ceiling Air inlet panel Canvas connection for air inlet panel Color White FXSN20 25 32AV1 350mm or mor...

Page 6: ...shortened Indoor units should be installed as far away from fluorescent light ing as possible 2 Use suspension bolts for installation Check whether the ceiling is strong enough to support the weight...

Page 7: ...the screws as shown in the drawing The paper pattern for installation is marked for 3 types of ceil ing openings Read the notations on the paper pattern care fully when installing 6 REFRIGERANT PIPIN...

Page 8: ...to insulate any field piping all the way to the piping connection inside the unit Any exposed piping may cause condensation or burns if touched CAUTION CAUTION TO BE TAKEN WHEN BRAZING REFRIGER ANT PI...

Page 9: ...rainage flow during COOL running explained under TEST OPERATION WHEN ELECTRIC WIRING WORK IS NOT FINISHED Remove the electric parts box lid connect a power supply and remote controller to the terminal...

Page 10: ...wn below Be sure to adhere it to avoid water from outside unit CAUTION When clamping the wires be sure no pressure is applied to the wire connections by using the included clamping material to make ap...

Page 11: ...e of the sort could damage the entire system 7 Use only specified wire and tightly connect wires to termi nals Be careful wires do not place external stress on termi nals Keep wiring in neat order and...

Page 12: ...llowing table explains FORCED OFF and ON OFF OPERATIONS in response to Input A 3 How to select FORCED OFF and ON OFF OPERATION Turn the power on and then use the remote controller to select operation...

Page 13: ...11 TEST OPERATION Refer to the installation manual of the outdoor unit The operation lamp of the remote controller will flash when an malfunction occurs Check the malfunction code on the liquid cryst...

Page 14: ...0901 FS HT 3P233622 5F EM08A072B...

Reviews: