4

Indoor unit installation

As for the parts to be used for installation work, be sure to use the
provided accessories and specified parts designated by our
company.

Make sure wiring, piping and drain piping meets your customer's
requirements and must comply with local and national regulations.

How to open and close the front panel 
(for FXLQ units only)

To open the front panel, remove 4 screws from the corner pieces,
unhook the corner pieces and remove the front panel as shown in the
figure below.

To close the front panel, use the opposite method.

Floorstanding installation

1

Level the indoor unit with the
leveling screws (accessory part).
If the floor is too uneven to level
the unit, place the unit on a flat
and level base.

2

If the unit is in danger of falling over, either fasten to the wall
using the holes provided, or fasten to the floor with a field
supplied floor fastener.

Wallmounted installation

1

Positioning of holes for fastening to the wall.
Unit of measurement = mm.

2

The legs can be removed if the indoor unit is to be hung on a
wall. To do so, remove the legs and mount the 2 decorationstrips
to the corner pieces as shown in the figures below.

For 

FXLQ

 units only

Ensure the unit is level when installed so that drainage
flows smoothly. If inclined, water can leak.

Make sure that the floor is strong enough to bear the unit
weight.

1

1

2

2

3

2

2

1

1

2

2

Check whether the wall is strong enough to bear the
weight of the unit. If there is a risk, reinforce the wall
before installing the unit.

Use the installation mount on the rear of the unit for
installation.

The unit requires minimum 100 mm
clearance on the bottomside for air
intake and maximum 20 mm
clearance from the wall by using
spacers (field supply).

Model

A (mm)

20 + 25

590

32 + 40

730

50 + 63

1010

20

A

205

205

192

232

1

1

5

6

7

3

5

2

6

5

2

5

4

4

A

100

A

≤200

Summary of Contents for FXLQ20P2VEB

Page 1: ...NSTALLATION AND OPERATION MANUAL FXLQ20P2VEB FXLQ25P2VEB FXLQ32P2VEB FXLQ40P2VEB FXLQ50P2VEB FXLQ63P2VEB FXNQ20P2VEB FXNQ25P2VEB FXNQ32P2VEB FXNQ40P2VEB FXNQ50P2VEB FXNQ63P2VEB System air conditioners...

Page 2: ...D OUT D F1 F2 F1 F2 Control box L N L N P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 3 1 4 2 L N L N L N L N 2 1 2 3 7 9 8 10 4 5 6 L N IN D OUT D F1...

Page 3: ...B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo c...

Page 4: ...d below Places with mineral oil or filled with oil vapour or spray like in kitchens Plastic parts may deteriorate Where corrosive gas like sulphurous gas exists Copper tubing and brazed spots may corr...

Page 5: ...class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Keep indoor unit outdoor unit power supply wiring a...

Page 6: ...otating the discharge grille NOTE Make sure no short circuit of air is caused when placing the unit directly under a windowsill 100 100 1000 20 A B C C A 1750 B 1750 C B b 20 20 C A A B C B Model 20 2...

Page 7: ...alling over either fasten to the wall using the holes provided or fasten to the floor with a field supplied floor fastener Wallmounted installation 1 Positioning of holes for fastening to the wall Uni...

Page 8: ...ghtening torque Overtightening may damage the flare and cause leaks When connecting the flare nut coat the flare inner surface with ether oil or ester oil and initially tighten 3 or 4 turns by hand be...

Page 9: ...ure from mixing into the system Vacuum pump Use a 2 stage vacuum pump with a non return valve Make sure the pump oil does not flow oppositely into the system while the pump is not working Use a vacuum...

Page 10: ...to the table below When attaching the control box lid make sure not to pinch any wires and make sure that the wiring does not come in contact with the piping and sharp edges After all wiring connectio...

Page 11: ...0 6 16 0 025 0 5 50 0 6 16 0 035 0 5 63 0 6 16 0 035 0 5 MCA Minimum Circuit Amps A MFA Maximum Fuse Amps A FLA Full Load Amps A NOTE For details refer to Electrical data in the technical data book P...

Page 12: ...operation 1 Wire specifications and how to perform wiring Connect input from outside to terminals T1 and T2 of the terminal board remote controller to transmission wiring 2 Actuation The following ta...

Page 13: ...t been finished Error code Meaning There is a short circuit at the forced off terminals T1 T2 U4 or UH The power on the outdoor unit is off The outdoor unit has not been wired for power supply Incorre...

Page 14: ...the air filter make sure to attach it Turn on the main power supply switch The control panel display lights up when the power is turned on To protect the unit turn on the main power switch at least 6...

Page 15: ...TIONAL ACCESSORY X18A CONNECTOR WIRING ADAPTOR FOR ELECTRICAL APPENDICES WIRED REMOTE CONTROLLER R1T THERMISTOR AIR SS1 SELECTOR SWITCH MAIN SUB TERMINAL BLOCK BLK BLACK PNK PINK CONNECTOR BLU BLUE RE...

Page 16: ...Copyright 2012 Daikin 4P323720 1 2012 06...

Reviews: