Only handle the indoor unit with gloves.

Sound pressure level is less than 70 dB (A).

This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for commer-
cial and household use by lay persons.

Do not install the air conditioner in the following locations:
1.

Where there is a high concentration of mineral oil spray
or vapour (e.g. a kitchen).
Plastic parts will deteriorate, parts may fall off and water 
leakage could result.

2.

Where corrosive gas, such as sulphurous acid gas, is
produced.
Corroding of copper pipes or soldered parts may result
in refrigerant leakage.

3.

Near machinery emitting electromagnetic radiation.
Electromagnetic radiation may disturb the operation of the
control system and result in a malfunction of the unit.

4.

Where flammable gas may leak, where there is carbon fibre 
or ignitable dust suspensions in the air, or where volatile
flammables such as paint thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.

Do not touch the heat exchanger fins.
Improper handling may result in injury.

Be very careful about product transportation.
Some products use PP bands for packaging. Do not use any
PP bands for a means of transportation. It is dangerous.

Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden
parts, may cause stabs or other injuries.
Tear apart and throw away plastic packaging bags so that
children will not play with them. If children play with a plastic
bag which was not torn apart, they face the risk of suffocation.

Do not turn off the power immediately after stopping operation.
Always wait at least 5 minutes before turning off the power.
Otherwise, water leakage and trouble may occur.

In a domestic environment this product may cause radio
interference in which case the user may be required to take
adequate measures.

Follow national standards for installation work.

2. BEFORE INSTALLATION

The accessories needed for installation must be retained in 
your custody until the installation work is completed. Do 
not discard them!

1. Decide upon a line of transport.
2. Leave the unit inside its packaging while moving, until

reaching the installation site. Where unpacking is unavoid-
able, use a sling of soft material or protective plates
together with a rope when lifting, to avoid damage or
scratches to the unit.

When moving the unit at or after opening, hold the unit by 
the hanger brackets. Do not apply force to the refrigerant 
piping, drain piping or flange parts.
Be sure to check the type of R410A refrigerant to be used 
before installing the unit.
(Using an incorrect refrigerant will prevent normal opera-
tion of the unit.)

For the installation of an outdoor unit, refer to the installation 
manual attached to the outdoor unit.

2-1 PRECAUTIONS

Be sure to instruct customers how to properly operate the
unit (operating different functions, and adjusting the temper-
ature ) by having them carry out operations themselves while 
looking at the operation manual.

Do not install in locations where the air contains high levels of 
salt such as that near the ocean and where voltage fluctuates 
greatly such as that in factories, or in vehicles or vessels.

2-2 ACCESSORIES

Check the following accessories are included with your unit.

2-3 OPTIONAL ACCESSORIES

This indoor unit requires one of the operation remote controls 
listed below.

FOR THE FOLLOWING ITEMS, TAKE SPECIAL 
CARE DURING CONSTRUCTION AND CHECK 
AFTER INSTALLATION IS FINISHED.

a. Items to be checked after completion of work

Name

Metal 
clamp (1)

Drain 
hose (2)

Insulation 
for fitting

Sealing pad

Quantity

1 pc.

1 pc.

1 each

1 each

Shape

for liquid pipe (3)

for gas pipe (4)

Large (5)

mid. (6)

Name

Screws for 
duct flanges 
(7)

Washer for 
hanging 
bracket (8)

Clamp

Washer 
fixing plate 
(11)

Quantity

1 set

8 pcs.

1 set

4 pcs.

Shape

Large (9)

8 pcs.

small (10)

4 pcs.

Name

Sealing 
material (12)

Air filter (13)

(Other)

• Operation manual
• Installation manual

(this manual)

Quantity

2 pcs.

1 pc.

Shape

Remote controller

Wired type

BRC1D52/BRC1D61/BRC1E51BRC2C51/
BRC1E52/BRC3A61

Wireless type

BRC4C62

Items to be checked

If not properly done, what is 
likely to occur

Check

Are the indoor and outdoor 
unit fixed firmly?

The units may drop, vibrate 
or make noise.

Is the gas leak test finished? 

It may result in insufficient 
cooling.

Is the unit fully insulated?

Condensate may drip.

Does drainage flow 
smoothly?

Condensate may drip.

Does the power supply volt-
age correspond to that 
shown on the name plate?

The unit may malfunction or 
the components burn out.

Are wiring and piping cor-
rect?

The unit may malfunction or 
the components burn out.

26 pcs.

4PEN365593-1C.book  Page 2  Thursday, April 20, 2017  1:00 PM

Summary of Contents for FXDQ15P3VE

Page 1: ...INSTALLATION MANUAL FXDQ15P3VE FXDQ20P3VE FXDQ25P3VE FXDQ32P3VE FXDQ40P3VE FXDQ50P3VE FXDQ63P3VE System Inverter Air Conditioners 4PEN365593 1C book Page 1 Thursday April 20 2017 1 00 PM...

Page 2: ...por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acor...

Page 3: ...do so during installation work may result in the unit falling and causing accidents Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried ou...

Page 4: ...unavoid able use a sling of soft material or protective plates together with a rope when lifting to avoid damage or scratches to the unit When moving the unit at or after opening hold the unit by the...

Page 5: ...allation Check whether the ceiling is strong enough to support the weight of the unit or not If there is a risk reinforce the ceiling before installing the unit To avoid contact with the fan one of th...

Page 6: ...prevent shaking Consult an architect or carpenter for details 4 Install the suspension bolts Use W3 8 to M10 suspension bolts Use a hole in anchor for existing ceilings and a sunken insert sunken anc...

Page 7: ...ion may form on the surface of the insulation if the temperature above the ceiling reaches 30 C or the humidity RH80 CAUTION Follow the points below Use a pipe cutter and flare suitable for the type o...

Page 8: ...phosphor copper brazer BCuP 2 JIS Z 3264 B Cu93P 710 795 ISO 3677 which does not require flux Using a flux containing chlorine may cause the piping to corrode Using a welding flux containing fluorine...

Page 9: ...fer to Fig 13 PRECAUTIONS Drain piping connections Do not connect the drain piping directly to sewage pipes that smell of ammonia The ammonia in the sewage might enter the indoor unit through the drai...

Page 10: ...tion area with aluminum tape or something similar to prevent air escaping CAUTION When attaching a duct to the intake side be sure to attach an air filter inside the air passage on the intake side Use...

Page 11: ...s Do not turn on the power supply circuit breaker or earth leak age breaker until all other work is done 9 2 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE Power related NOTES 1 Shows only in case o...

Page 12: ...power sup ply wiring to the remote controller or transmission wiring terminal block Doing so can destroy the entire system Connecting electrical wiring remote controller wiring and transmission wiring...

Page 13: ...For group control or use with 2 remote controllers Terminal block Tightening torque N m Remote controller transmission wiring terminal block 6P 0 79 0 97 Power supply wiring terminal block 3P 1 18 1...

Page 14: ...or remote controller to achieve remote control See the 11 FIELD SETTING AND TEST RUN for details on operation 10 4 CENTRALIZED CONTROL For centralized control it is necessary to designate the group No...

Page 15: ...tion man ual included with the wireless remote controller for details on how to make the settings 3 Perform a test run according to the outdoor unit s installation manual The operation lamp of the rem...

Page 16: ...GHT EMITTINGDIODE S NPL PRESSURESENSOR LOW HAP LIGHT EMITTINGDIODE SERVICEMONITOR GREEN S PH HPS PRESSURESWITCH HIGH HIGH VOLTAGE HIGH VOLTAGE S PL PRESSURESWITCH LOW IES INTELLIGENT EYESENSOR S T THE...

Page 17: ...4P365593 1C 2017 03 Copyright 2013 Daikin 4PEN365593 1C book Page 1 Thursday April 20 2017 1 00 PM...

Reviews: