Troubleshooting
SiUS091601E
73
Service Diagnosis
Troubleshooting
Check No.03
Refer to P.102
Caution
OK?
NO
YES
YES
NO
Check No. 03
Check No. 03
Check No. 03
NO
YES
YES
YES
NO
NO
YES
NO
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Check the connector for
connection.
Note: The motor may break when the
motor connector is disconnected
with the power supply on.
(Turn off the power supply before
connecting the connector also.)
∗
To secure the connection,
once disconnect the connector
and then reconnect it.
Foreign matters in or
around the fan?
Is the rotation pulse
generated?
Rotate the fan by hand.
Turn the power on again.
Check the fan motor for
breakdown or short circuit.
Check the motor control voltage.
Check the indoor unit PCB for
rotation pulse.
Fan rotates smoothly?
Resistance OK?
Is the motor control
voltage 15 VDC
generated?
Correct the connection.
Remove the foreign matters.
Replace the indoor fan motor.
Replace the indoor unit PCB
(control PCB).
Replace the indoor fan motor.
Replace the indoor unit PCB
(control PCB).
Turn off the power supply.
(Unplug the power cable or turn
the breaker off.)
(R20165)
YES
NO
NO
Abnormal
sound occurs?
Is the rubber cushion
properly fitted?
YES
Correct the position of
rubber cushion or replace
the rubber cushion.
Replace the bearing rubber
cushion.
Rubber
cushion
Bearing
rubber
cushion
FTX Series
Summary of Contents for FVXS09NVJU
Page 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5 ...
Page 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57 ...
Page 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition ...