Outdoor Unit
SiUS091601E
17
Printed Circuit Board Connector Wiring Diagram
2.2
RXL12QMVJU
Main PCB
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for DC fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) HL1, HN1, S
Connector for terminal board
7) E1, E2
Terminal for ground wire
8) U, V, W
Connector for compressor
9) FU1, FU2
Fuse (3.15 A, 250 V)
10)FU3
Fuse (20 A, 250 V)
11)J6
Jumper for facility setting
∗
Refer to page 121 for detail.
12)LED A
LED for service monitor (green)
13)V2, V3, V150
Varistor
E1, E2
FU3
V2
V3
FU1
V150
FU2
U, V, W
S20
LED A
S90
J6
S40
S70
2P381219-4
HL1, HN1, S
S80