![Daikin FVXS09NVJU Service Manual Download Page 29](http://html.mh-extra.com/html/daikin/fvxs09nvju/fvxs09nvju_service-manual_501431029.webp)
SiUS091601E
Outdoor Unit
Printed Circuit Board Connector Wiring Diagram
18
2.3
RXL15QMVJU
Main PCB
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for DC fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) HL1, HN1, S
Connector for terminal board
7) E1, E2
Terminal for ground
8) U, V, W
Connector for compressor
9) FU1, FU2
Fuse (3.15 A, 250 V)
10)FU3
Fuse (30 A, 250 V)
11)J6
Jumper for facility setting
∗
Refer to page 121 for detail.
12)LED A
LED for service monitor (green)
13)V1, V2, V3
Varistor
U, V, W
FU3
FU1
FU2
V3
V2
V1
S20
S80
S40
S90
J6
S70
2P382390-14
E1, E2
HL1, HN1, S
LED A
Summary of Contents for FVXS09NVJU
Page 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5 ...
Page 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57 ...
Page 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition ...