SiUS091601E
Functions
List of Functions
2
1. Functions
Category
Functions
FTX
09/
12NM
V
JU
RX
L09/
12
Q
M
V
J
U
FTX
15N
M
V
J
U
RX
L15QM
V
JU
Category
Functions
FTX
09/
12NM
V
JU
RX
L09/
12
Q
M
V
J
U
FTX
15N
M
V
J
U
RX
L15QM
V
JU
Basic
Functions
Inverter (with inverter power control)
z
z
Health &
Cleanliness
Air-purifying filter
—
—
Operation limit for cooling (°CDB)
10 ~
46
10 ~
46
Photocatalytic deodorizing filter
—
—
Air-purifying filter with photocatalytic
deodorizing function
—
—
Operation limit for cooling (°FDB)
50 ~
114.8
50 ~
114.8
Titanium apatite photocatalytic
air-purifying filter (option)
z
z
Operation limit for heating (°CWB)
-25 ~
15.6
-25 ~
15.6
Air filter (prefilter)
z
z
Operation limit for heating (°FWB)
-13 ~
60
-13 ~
60
Wipe-clean flat panel
z
z
Washable grille
—
—
PAM control
z
z
MOLD PROOF operation
—
—
Standby electricity saving
z
z
Good-sleep cooling operation
—
—
Compressor
Oval scroll compressor
—
—
Timer
WEEKLY TIMER
—
—
Swing compressor
z
z
Count up-down ON/OFF timer
z
z
Rotary compressor
—
—
24-hour ON/OFF TIMER
—
—
Reluctance DC motor
z
z
NIGHT SET mode
z
z
Comfortable
Airflow
Power-airflow flap (horizontal blade)
z
—
Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
z
z
Power-airflow dual flaps
—
z
Self-diagnosis (R/C, LED)
z
z
Power-airflow diffuser
—
—
Wiring error check function
—
—
Wide-angle louvers (vertical blade)
z
z
Anti-corrosion treatment of outdoor heat
exchanger
z
z
Auto-swing (up and down)
z
z
Auto-swing (right and left)
—
—
Flexibility
Multi-split/split type compatible indoor
unit
—
—
3-D airflow
—
—
COMFORT AIRFLOW operation
z
z
H/P, C/O compatible indoor unit
—
—
Comfort
Control
Auto fan speed
z
z
Flexible power supply correspondence
—
—
Indoor unit quiet operation
z
z
Chargeless
32.8 ft
(10 m)
32.8 ft
(10 m)
NIGHT QUIET mode (automatic)
—
—
OUTDOOR UNIT QUIET operation
(manual)
—
—
Either side drain (right or left)
z
z
Power selection
—
—
INTELLIGENT EYE operation
—
—
Low temperature cooling operation
(–15°C) (5°F)
z
z
Quick warming function
z
z
Hot-start function
z
z
°F/°C changeover R/C temperature
display (factory setting: °F)
z
z
Automatic defrosting
z
z
Operation
Automatic operation
z
z
Remote
Control
5-rooms centralized controller (option)
z
z
Program dry function
z
z
Remote control adaptor
(normal open-pulse contact) (option)
z
z
Fan only
z
z
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
—
—
Remote control adaptor
(normal open contact) (option)
z
z
Inverter POWERFUL operation
z
z
DIII-NET compatible (adaptor) (option)
z
z
Priority-room setting
—
—
Remote
Controller
Wireless
z
z
COOL/HEAT mode lock
—
—
Wired (option)
z
z
HOME LEAVE operation
—
—
ECONO operation
z
z
Indoor unit
ON/OFF
button
z
z
Signal receiving sign
z
z
R/C with back light
z
z
Temperature display
—
—
Note:
z
: Available
— : Not available
Summary of Contents for FVXS09NVJU
Page 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5 ...
Page 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57 ...
Page 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition ...