background image

2

English

To gain full advantage of the air conditioner’s func-
tions and to avoid malfunction due to mishandling, 
please read this operation manual carefully before 
use.
This air conditioner is classified under “appliances 
not accessible to the general public”.

• The precautions described herein are classified 

as WARNING and CAUTION. They both contain 
important information regarding safety. Be sure 
to observe all precautions without fail.

WARNING

...Failure to follow these instructions 

properly may result in personal 
injury or loss of life.

CAUTION

....Failure to observe these instruc-

tions properly may result in prop-
erty damage or personal injury, 
which may be serious depending 
on the circumstances.

• After reading, keep this manual in a convenient 

place so that you can refer to it whenever nec-
essary. If the equipment is transferred to a new 
user, be sure also to hand over the manual.

WARNING

Be aware that prolonged, direct exposure to 
cool or warm air from the air conditioner, or to 
air that is too cool or too warm can be harmful 
to your physical condition and health.

When the air conditioner is malfunctioning 
(giving off a burning odour, etc.) turn off the 
power to the unit and contact your local 
dealer.

Continued operation under such circumstances may 
result in a failure, electric shocks or fire hazards.

Consult your local dealer about installation work.

Doing the work yourself may result in water leak-
age, electric shocks or fire hazards.

Consult your local dealer regarding modification, 
repair and maintenance of the air conditioner.

Improper workmanship may result in water leak-
age, electric shocks or fire hazards.

Do not place objects, including rods, your 
fingers, etc., in the air inlet or outlet.

Injury may result due to contact with the air con-
ditioner's highspeed fan blades.

Beware of fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, 
i.e. not generating cool or warm air, refrigerant 
leakage could be the cause. Consult your dealer 
for assistance. The refrigerant used for the air 
conditioner is safe and normally does not leak.  
However, if the refrigerant leaks and gets in con-
tact with a naked burner, heater or cooker, it may 
generate hazardous compounds. Turn off the air 
conditioner and call the dealer. Make sure to turn 

2. SAFETY PRECAUTIONS

on the air conditioner after the qualified service 
person confirms that the leakage is repaired.

Consult your local dealer regarding what to 
do in case of refrigerant leakage.

When the air conditioner is to be installed in a 
small room, it is necessary to take proper mea-
sures so that the amount of any leaked refriger-
ant does not exceed the concentration limit in 
the event of a leakage. Otherwise, this may lead 
to an accident due to oxygen depletion.

Contact professional personnel about 
attachment of accessories and be sure to use 
only accessories specified by the manufac-
turer.

If a defect results from your own workmanship, it 
may result in water leaks, electric shock or fire.

Consult your local dealer regarding reloca-
tion and reinstallation of the air conditioner.

Improper installation work may result in leakage, 
electric shocks or fire hazards.

Be sure to use fuses with the correct ampere 
reading.

Do not use improper fuses, copper or other wires 
as a substitute, as this may result in electric 
shock, fire, injury or damage to the unit.

Be sure to earth the unit.

Do not earth the unit to a utility pipe, lightning 
conductor or telephone earth lead.
Imperfect earthing may result in electric shocks 
or fire.
A high surge current from lightning or other 
sources may cause damage to the air condi-
tioner.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may 
result in electric shocks or fire.

Consult the dealer if the air conditioner sub-
merges owing to a natural disaster, such as a 
flood or typhoon.

Do not operate the air conditioner in that case, or 
otherwise a malfunction, electric shock, or fire 
may result.

Start or stop the air conditioner with the 
remote controller.  Never use the power sup-
ply breaker for this purpose. 

Otherwise, it may cause fire or water leakage. 
Furthermore, if an automatic reset control is pro-
vided against power failure and the power is 
recovered, the fan will rotate suddenly and may 
cause injury. 

Do not use the product in the atmosphere 
contaminated with oil vapor, such as cook-
ing oil or machine oil vapor.

Oil vapor may cause crack damage, electric 
shocks, or fire.

Do not use the product in places with exces-
sive oily smoke, such as cooking rooms, or 
in places with flammable gas, corrosive gas, 
or metal dust.

UntitledBook1.book  Page 2  Wednesday, December 14, 2011  4:14 PM

Summary of Contents for FVQ100CVEB

Page 1: ...Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugues 3P170549 14G book Page 1 Friday Octobe...

Page 2: ...st dirigido a la unidad interior Consulte tambi n los manuales de instrucciones proporcionados con la unidad exterior y el mando a distancia La ringraziamo di aver acquistato questo condizionatore d a...

Page 3: ...1 3P170549 14G book Page 2 Friday October 28 2011 3 04 AM...

Page 4: ...rsonas Contacte por favor con el instalador o con las autoridades locales para obtener m s informaci n Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normat...

Page 5: ...FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm the...

Page 6: ...ditioner and call the dealer Make sure to turn 2 SAFETY PRECAUTIONS on the air conditioner after the qualified service person confirms that the leakage is repaired Consult your local dealer regarding...

Page 7: ...dripping resulting in fouling or failure of the object concerned Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the b...

Page 8: ...er or detergent may deteriorate the insulation of electric components and result in burn out of these components Grille stopper Grille fixture Suction grille Front panel Tapping screw CAUTION ELECTRIC...

Page 9: ...pe and cause water leakage If it occurs stop the air con ditioner and consult with you dealer for assistance 4 INSTALLATION SITE Read the operation manual that came with the remote controller Operatin...

Page 10: ...e airflow rate that are being set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lower ing the indoor temperature and automatically sets the airflow rate and t...

Page 11: ...he air conditioner Adjusting up and down airflow by hand 2 2 1 1 Group No The group No is stamped on the top and back of each flap NOTE Operating the unit with overlapping upper lower and interlocking...

Page 12: ...e It is advisable to start operation in advance using TIMER OPERA TION ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE WARNING Do not use flammable gases such as hair or insect spray...

Page 13: ...Close the suction grille using the reverse proce dure of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 After turning on the power p...

Page 14: ...MAINTENANCE on page 8 The following symptoms do not indicate air condi tioner malfunction HEATING OPERATION within 6 hours after the power is supplied to the power circuit breaker Some models perform...

Page 15: ...is higher than the set temperature After a while the swing operation starts Refer to Movement of left and right airflow flaps on page 7 The airflow direction display of the remote controller differs...

Page 16: ...off position Do not turn the power on with the power circuit 10 TROUBLE SHOOTING breaker switch in the trip position Contact your dealer Check if there is a power failure Wait until power is restored...

Page 17: ...air it yourself In such cases always ask your local dealer At this time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the meas...

Page 18: ...3P170549 14J EM11A037A 1201 HT SP_00_CV_3P170549 14G fm Page 5 Tuesday December 13 2011 6 14 PM...