background image

4

English

Never touch the internal parts of the remote 
controller.

Do not remove the front panel. Touching certain 
internal parts will cause electric shocks and 
damage to the unit. Please consult your dealer 
about checking and adjustment of internal parts.

Do not leave the remote controller wherever 
there is a risk of wetting.

If water gets into the remote controller there is a 
risk of electrical leakage and damage to elec-
tronic components.

• NOTE TO SURVICE PERSONNEL

CAUTION

Read the following for the safety.

Do not operate the unit while the suction grille is 
open.

Fan may rotate and cause accident.

Make sure to screw the suction grille stopper.

If the screw is not completely tightened, the suc-
tion grille may come off and you may cut your fin-
gers with the fan.

After the installation or service maintenance, 
make sure to put the grille stopper to where it was 
with screws.
(R & L, total 2:see the below.)

WARNING

May cause electric shock, ignition, fire

Before starting the inspection of the electrical 
parts (control box, fan motor, drain pump, etc.), 
be sure cut off the all air-conditioner power (adap-
tor for wiring power is included) or you may get an 
electric shock.

When cleaning the heat exchanger, be sure to 
remove the switch box, fan motor and drain 
pump.
Water or detergent may deteriorate the insulation 
of electric components and result in burn-out of 
these components.

Grille stopper

Grille fixture

Suction grille

Front panel

Tapping screw

CAUTION! ELECTRIC SHOCK

Due to high voltage, do not open control box  lid for 
ten minutes after the safety breaker is switched 
off.

After the box is opened, measure the voltages of 
the points shown below printed circuit board with 
a tester and confirm that the voltages are not 
higher than DC50V.
Do not touch live parts when carrying out this work.

After power failure, operation will restart automat-
ically.

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING                                                              [°C]

HEATING                                                             [°C]

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 16°C to 32°C.

3. OPERATION RANGE

OUTDOOR 

UNIT

INDOOR

OUTDOOR 

TEMPERA-

TURE

TEMPERA-

TURE

HUMI-

DITY

RZQG

DB

18 to 37

80% or 
below

DB

–15 to 50

WB 12 to 28

RZQSG71·
100·125·
140

DB

21 to 37

80% or 
below

DB

–10 to 43

WB 14 to 28

OUTDOOR 

UNIT

INDOOR 

TEMPERA-

TURE

OUTDOOR 

TEMPERATURE

RZQG

DB

10 to 27

DB

–19.5 to 21

WB

–20 to 15.5

RZQSG71

DB

10 to 30

DB

– 14 to 21

WB

–15 to 15.5

RZQSG100·
125·140

DB

10 to 28

DB

– 14 to 21

WB

–15 to 15.5

Residual voltage 
measurement points

+
C

-

+

0

- C

Printed circuit board

Control box

UntitledBook1.book  Page 4  Wednesday, December 14, 2011  4:14 PM

Summary of Contents for FVQ100CVEB

Page 1: ...Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugues 3P170549 14G book Page 1 Friday Octobe...

Page 2: ...st dirigido a la unidad interior Consulte tambi n los manuales de instrucciones proporcionados con la unidad exterior y el mando a distancia La ringraziamo di aver acquistato questo condizionatore d a...

Page 3: ...1 3P170549 14G book Page 2 Friday October 28 2011 3 04 AM...

Page 4: ...rsonas Contacte por favor con el instalador o con las autoridades locales para obtener m s informaci n Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normat...

Page 5: ...FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm the...

Page 6: ...ditioner and call the dealer Make sure to turn 2 SAFETY PRECAUTIONS on the air conditioner after the qualified service person confirms that the leakage is repaired Consult your local dealer regarding...

Page 7: ...dripping resulting in fouling or failure of the object concerned Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the b...

Page 8: ...er or detergent may deteriorate the insulation of electric components and result in burn out of these components Grille stopper Grille fixture Suction grille Front panel Tapping screw CAUTION ELECTRIC...

Page 9: ...pe and cause water leakage If it occurs stop the air con ditioner and consult with you dealer for assistance 4 INSTALLATION SITE Read the operation manual that came with the remote controller Operatin...

Page 10: ...e airflow rate that are being set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lower ing the indoor temperature and automatically sets the airflow rate and t...

Page 11: ...he air conditioner Adjusting up and down airflow by hand 2 2 1 1 Group No The group No is stamped on the top and back of each flap NOTE Operating the unit with overlapping upper lower and interlocking...

Page 12: ...e It is advisable to start operation in advance using TIMER OPERA TION ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE WARNING Do not use flammable gases such as hair or insect spray...

Page 13: ...Close the suction grille using the reverse proce dure of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 After turning on the power p...

Page 14: ...MAINTENANCE on page 8 The following symptoms do not indicate air condi tioner malfunction HEATING OPERATION within 6 hours after the power is supplied to the power circuit breaker Some models perform...

Page 15: ...is higher than the set temperature After a while the swing operation starts Refer to Movement of left and right airflow flaps on page 7 The airflow direction display of the remote controller differs...

Page 16: ...off position Do not turn the power on with the power circuit 10 TROUBLE SHOOTING breaker switch in the trip position Contact your dealer Check if there is a power failure Wait until power is restored...

Page 17: ...air it yourself In such cases always ask your local dealer At this time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the meas...

Page 18: ...3P170549 14J EM11A037A 1201 HT SP_00_CV_3P170549 14G fm Page 5 Tuesday December 13 2011 6 14 PM...

Reviews: