background image

8

English

Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or 
cooling.
Not doing so wastes electricity. 

When the display shows “

”, ask a qualified 

service person to clean the filters. 
(Refer to “MAINTENANCE” on page 8.) 
Operating the unit with stained air filter may 
decrease capacity or cause malfunction.

Install TVs, radios, and stereos 1 m or more away 
from the indoor unit and remote controller.
Images may become fuzzy and noise may be 
generated.

Turn off the power circuit breaker when it is not in 
use for a long period. When the main power switch 
is turned on, small amount of power is consumed 
even if the system is not in operation. (*1) Turn off 
the power circuit breaker for saving energy. When 
reoperating, turn on the power circuit breaker 6 
hours before operation for smooth running. 
(Refer to “MAINTENANCE” on page 8.) (*2)

*1 The consumed power while the outdoor unit is 

not in operation depends on the model.

*2 The setting before the power circuit breaker is 

cut off is stored. (The timer setting is cleared.)

Fully use the function of airflow direction adjust.
Cold air gathers on the floor, and warm air gathers 
in the ceiling.
Set the air discharge to horizontal direction during 
COOLING or PROGRAM DRY OPERATION, and 
set it downwards during HEATING OPERATION.
Do not let the air blow directly to a person.

Use the TIMER OPERATION effectively.
It takes some time until the indoor temperature 
reaches the set temperature. It is advisable to 
start operation in advance using TIMER OPERA-
TION.

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

WARNING

Do not use flammable gases (such as hair or 
insect sprays) near the indoor unit.
Do not wipe the indoor unit with benzene or thin-
ner.
This may cause cracking, electric shock, or fire.

CAUTION

Do not wash the air conditioner with water
Doing so may result in an electric shock and fire.

To clean the air conditioner, be sure to stop oper-
ation, and turn the power circuit breaker off. It may 
cause electric shock or injury.

NOTE

Do not remove the air filter except for during 
cleaning. Doing so may damage the unit.

Do not install anything (such as kitchen paper) 
other than the approved air filters on the air inlet. 
Doing so may lower operation efficiency and 
cause freezing or leakage.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

” on 

the remote controller (TIME TO CLEAN AIR FIL-
TER).

The display shows after a certain period of oper-
ation.

NOTE

The time until the display appears can be 
changed. For information on using the air condi-
tioner in a dirty place, contact your dealer.

Once the staining on the air filter cannot be 
removed, replace the filter with a new one.
(The air filter for replacement is provided as an 
optional part.)

Do not use the air conditioner in an oily environ-
ment. If oil adheres, clean the air filter and suction 
grille regularly.

8. MAINTENANCE

(FOR SERVICE PERSONNEL)

Stain

Time until display 

appears

Standard

2,500 hours

(approx. 1 year)

When the amount of 

staining is large

1,250 hours

(approx. a half year)

UntitledBook1.book  Page 8  Wednesday, December 14, 2011  4:14 PM

Summary of Contents for FVQ100CVEB

Page 1: ...Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugues 3P170549 14G book Page 1 Friday Octobe...

Page 2: ...st dirigido a la unidad interior Consulte tambi n los manuales de instrucciones proporcionados con la unidad exterior y el mando a distancia La ringraziamo di aver acquistato questo condizionatore d a...

Page 3: ...1 3P170549 14G book Page 2 Friday October 28 2011 3 04 AM...

Page 4: ...rsonas Contacte por favor con el instalador o con las autoridades locales para obtener m s informaci n Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normat...

Page 5: ...FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm the...

Page 6: ...ditioner and call the dealer Make sure to turn 2 SAFETY PRECAUTIONS on the air conditioner after the qualified service person confirms that the leakage is repaired Consult your local dealer regarding...

Page 7: ...dripping resulting in fouling or failure of the object concerned Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the b...

Page 8: ...er or detergent may deteriorate the insulation of electric components and result in burn out of these components Grille stopper Grille fixture Suction grille Front panel Tapping screw CAUTION ELECTRIC...

Page 9: ...pe and cause water leakage If it occurs stop the air con ditioner and consult with you dealer for assistance 4 INSTALLATION SITE Read the operation manual that came with the remote controller Operatin...

Page 10: ...e airflow rate that are being set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lower ing the indoor temperature and automatically sets the airflow rate and t...

Page 11: ...he air conditioner Adjusting up and down airflow by hand 2 2 1 1 Group No The group No is stamped on the top and back of each flap NOTE Operating the unit with overlapping upper lower and interlocking...

Page 12: ...e It is advisable to start operation in advance using TIMER OPERA TION ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE WARNING Do not use flammable gases such as hair or insect spray...

Page 13: ...Close the suction grille using the reverse proce dure of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 After turning on the power p...

Page 14: ...MAINTENANCE on page 8 The following symptoms do not indicate air condi tioner malfunction HEATING OPERATION within 6 hours after the power is supplied to the power circuit breaker Some models perform...

Page 15: ...is higher than the set temperature After a while the swing operation starts Refer to Movement of left and right airflow flaps on page 7 The airflow direction display of the remote controller differs...

Page 16: ...off position Do not turn the power on with the power circuit 10 TROUBLE SHOOTING breaker switch in the trip position Contact your dealer Check if there is a power failure Wait until power is restored...

Page 17: ...air it yourself In such cases always ask your local dealer At this time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the meas...

Page 18: ...3P170549 14J EM11A037A 1201 HT SP_00_CV_3P170549 14G fm Page 5 Tuesday December 13 2011 6 14 PM...

Reviews: