![Daikin FTY25GXV1 Service Manual Download Page 88](http://html.mh-extra.com/html/daikin/fty25gxv1/fty25gxv1_service-manual_2459572088.webp)
SiBE01-829
Indoor Unit
Removal Procedure
77
5
Unscrew the flare nut
for liquid piping by 2
wrenches.
2. Removing the indoor unit
When the pipes are
disconnected, protect the
both openings of pipe side
and unit side from entering
of moisture.
1
Remove the indoor unit
from the installation
plate.
2
Release the hook of the
piping fixture on the
back of the unit.
Step
Procedure
Points
(R8018)
Gas piping
Liquid piping
(R8618)
Auxiliary piping
Piping fixture
(R8038)
(R8039)