SiBE01-829
Indoor Unit
Removal Procedure
65
1.4
Removal of
Horizontal
/
Vertical Blades
and
Safety Net
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Removing the horizontal
blade (large)
1
Open the horizontal
blade.
2
Unfasten the center
fixing shaft while
bending the horizontal
blade slightly.
Cautions on Mounting
The center fixing shaft can
be removed easily by
bending the blade.
Cautions on Mounting
1. Since key pattern hook is
provided, rotate the blades
and fit it to the right pivot
first.
2. Fit the blades to the center
and left pivots.
3
Unfasten the left fixing
shaft of the horizontal
blade.
4
Unfasten the right fixing
shaft of the horizontal
blade.
(R8580)
Horizontal blade
(R8581)
(R7993)
(R7995)
Key
Left
Right
Summary of Contents for FTY25GXV1
Page 1: ...SiBE01 829 Applied Models Non Inverter Pair Heat Pump SPLIT Pair Wall Mounted Type G Series ...
Page 5: ...SiBE01 829 iv Table of Contents Index i Drawings Flow Charts iii ...
Page 11: ...Introduction SiBE01 829 x ...
Page 12: ...SiBE01 829 List of Function 1 Part 1 List of Function 1 Functions 2 ...
Page 15: ...Functions SiBE01 829 4 List of Function ...
Page 16: ...SiBE01 829 Specifications 5 Part 2 Specifications 1 Specifications 6 ...
Page 19: ...Specifications SiBE01 829 8 Specifications ...
Page 49: ...Instructions SiBE01 829 38 Operation Manual ...
Page 69: ...Check SiBE01 829 58 Service Diagnosis ...
Page 111: ...Outdoor Unit SiBE01 829 100 Removal Procedure ...
Page 119: ...Wiring Diagrams SiBE01 829 108 Appendix ...