SiBE01-829
Outdoor Unit
Removal Procedure
89
7
Loosen the screw to
remove the fan motor
fixing frame.
When reassembling, fit the
lower hook into the bottom
frame.
8
Loosen the 2 fixing
hooks and release the
lead wire.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
propeller fan)
Step
Procedure
Points
Fan motor fixing frame
(R8565)
(R7206)
(R8540)
Hook
Hook
(R3249)
Lead wire
Propeller fan