![Daikin FTY25GXV1 Service Manual Download Page 78](http://html.mh-extra.com/html/daikin/fty25gxv1/fty25gxv1_service-manual_2459572078.webp)
SiBE01-829
Indoor Unit
Removal Procedure
67
3. Removing the
vertical
blade
Six vertical blades are
united as a set.
(It is impossible to replace
only one blade.)
The set of blades is not
marked for difference
between right and left.
1
Unfasten the hooks at
the upper 2 positions.
2
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
3
Remove the vertical
blade toward yourself.
Repeat the same procedure
to remove the vertical blade
on the other side.
Step
Procedure
Points
Hooks
(R8586)
(R8587)
(R8588)
(R8589)