![background image](http://html1.mh-extra.com/html/daikin/ftxta30aw/ftxta30aw_service-manual_4214030085.webp)
ESIE17-19C
|
Part 3. Repair
3.3. Unit specific repair procedures
19/08/19
|
Version 1.1
Page 85
Optimized Heating 4
Figure 3-18: Removing the compressor
1. Screw
6. Nut
2. Partition plate assembly
7. Compressor
3. Terminal cover
8. Putty
4. Compressor wiring
9. Dampers
5. Compressor pipe
10. Bushing
1
2
1
3
8
7
4
5
5
8
9
3
3
8
9