![background image](http://html1.mh-extra.com/html/daikin/ftxta30aw/ftxta30aw_service-manual_4214030079.webp)
ESIE17-19C
|
Part 3. Repair
3.3. Unit specific repair procedures
19/08/19
|
Version 1.1
Page 79
Optimized Heating 4
3.3.2.2. Removing switch box
PRELIMINARY ACTIONS
1. Switch off the Daikin unit via the user interface.
2. Switch off the Daikin unit with the field supplied circuit breaker.
3. Remove plate work when required, refer to
PROCEDURE
Removal
1. Remove the insulation (
).
2. Unplug all connectors from the main PCB (
), see
"Component checklist" on page 118
3. Remove all electrical power wiring (
4. Remove the screws (
) that fix the wire clamp (
), remove the wire clamp (
5. Remove the screws (
) that fix the right side plate assembly (
).
6. Cut the cable tie (
).
) from the Daikin unit.
W
ARNING
: R
ISK
OF
F
IRE
When reconnecting a connector to the PCB, do not apply force, as this may damage the connector or connector pins of
the PCB.