4.

Wiring.

, install as described in the installation manual supplied with the Multi outdoor unit.

1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corre-

sponding terminals.

3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote control cable and attach the S21. (Refer to 5. When connecting to 

an HA system.)

6) Shape the wires so that the service lid fits securely, then close service lid.

WARNING

1) Do not use tapped wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical 

shock, or fire.

2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the 

terminal block.) Doing so may cause electric shock or fire.

3) Do not connect the power wire to the indoor unit. Doing so may cause electric shock or fire.

5.

When connecting to an HA system.

1) Remove the front grille. (3 screws)
2) Remove the electrical wiring box. (1 screw)
3) Remove the metal plate electrical wiring cover. (4 tabs)
4) Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure.
5) Replace the electrical wiring cover as it was,  and pull the harness around, as shown in the figure.

With a Multi indoor unit

Shape wires so 
that the service 
lid will fit securely.

Terminal block

Electrical component box

Wire retainer

Firmly secure wire retainer 
so that wires sustain no 
external stress.

Use the 
specified 
wire type.

1
2
3

1 2 3

L N

When wire length exceeds 
10m, use 2.0mm diameter wires.

H05RN

Firmly fix the wires with 
the terminal screws.

Outdoor unit

Indoor 
unit

Firmly fix the wires with 
the terminal screws.

Screw

HA cord

HA connector
(S21)

Tab

Tab

Push

Slide

Push

Metal plate 
electrical cover

Tab

Push

Main body

Notched part

4)

5) Replace the electrical 

wiring cover as it was,  
and pull the harness 
around, as shown 
in the figure.

Attach the connection cord to 
the S21 connector and pull the 
harness out through the 
notched part in the figure.

3) Remove the metal 

plate electrical 
wiring cover.

01_EN_3P190114-1D.fm  Page 8  Monday, August 23, 2010  3:35 PM

Summary of Contents for FTXS50FV1B

Page 1: ...Espa ol Italiano Portugues T rk e Deutsch Installation manual R410A Split series Installationsanleitung Split Baureihe R410A Manuel d installation S rie split R410A Montagehandleiding R410A Split sys...

Page 2: ...04 108 EC 3SB64526 5F Shinri Sada Manager Quality Control Department 25th of Nov 2009 DAIKIN TCF 015 M18 11 2009 FTKS50FV1B FTKS60FV1B FTKS71FV1B FTXS50FV1B FTXS60FV1B FTXS71FV1B FTX50GV1B FTX60GV1B F...

Page 3: ...mping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Insta...

Page 4: ...ted 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site where remote control signals are properly received by the indoor unit within 7 metres Installa...

Page 5: ...nd firmly engage the upper hooks 3 locations 2 Install 3 screws of the front grille 3 Install the air filter and then mount the front panel 3 How to set the different addresses When two indoor units a...

Page 6: ...ounting plate should be installed on a wall which can support the weight of the indoor unit D E Remote controller holder Wireless remote controller Before screwing the remote controller holder to the...

Page 7: ...crews Recommended mounting plate retention spots and Dimensions 125 60 83 413 5 44 5 290 52 1050 99 5 52 90 55 100 100 Through the wall hole 80mm Drain hose position 80 80 Recommended mounting plate r...

Page 8: ...the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to Installation tips 5 Pass the interconnecting wires from the outdoor unit through the feed through wall...

Page 9: ...late hooks Secure indoor unit to the mounting plate with screws M4 12L 3 3 Wall Embedded Piping Follow the instructions given under 1 Insert the drain hose to this depth so it wont be pulled out of th...

Page 10: ...ck or fire 5 When connecting to an HA system 1 Remove the front grille 3 screws 2 Remove the electrical wiring box 1 screw 3 Remove the metal plate electrical wiring cover 4 tabs 4 Attach the connecti...

Page 11: ...oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with the unit 4 Do...

Page 12: ...nd liquid piping and to provide insulation dimen sions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side Gas pipe thermal insulation Liquid pip...

Page 13: ...tioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If...

Page 14: ...1010 HT 3P190114 1D M06B094D Two dimensional bar code is a code for manufacturing 00_CV_3P190114 1D fm Page 2 Monday August 23 2010 3 29 PM...