Outdoor Unit
SiBE041102_A
8
Printed Circuit Board Connector Wiring Diagram
2. Outdoor Unit
Connectors and
Other Parts
PCB Detail
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) HL1, HN1, S
Connector for terminal board
7) E1, E2
Terminal for earth
8) HR1, HR2
Connector for reactor
9) U, V, W
Connector for compressor
10)LED A
LED for service monitor (green)
11)FU1, FU2
Fuse (3.15 A, 250 V)
12)FU3
Fuse (20 A, 250 V)
13)V2, V3, V150
Varistor
14)J5
Jumper for improvement of defrost performance
∗
Refer to page 140 for detail.
FU3
V3
V2
FU1
E1, E2
HR1
FU2
HR2
U, V, W
J5
S90
S40
S20
S80
S70
V150
S
LED A
HN1
HL1
2P271899-1