![background image](http://html2.mh-extra.com/html/daikin/ftxn25kev1b/ftxn25kev1b_service-manual_4700136132.webp)
Outdoor Unit
SiBE041102_A
122
Removal Procedure
2.3
Removal of Electrical Box / PCB
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the PCB.
Preparation
Remove the panels
according to the “Removal
of Outer Panels”.
1
Remove the screws
and release the
connecting wires.
2
Remove the 3 screws
and remove the wire
clamp.
3
Disconnect the
connector [S70] and
release the fan motor
lead wire from the hook.
[S70]: fan motor
4
Release the fan motor
lead wire from the 3
hooks.
(R14496)
(R14497)
Wire
clamp
[S70]
Hook
Fan motor
lead wire
(R14491)
(R14492)