Outdoor Unit
SiBE041102_A
132
Removal Procedure
2.5
Removal of Four Way Valve
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
1
Remove the screw and
remove the four way
valve coil.
2
Remove the terminal
cover.
3
Disconnect the
terminals of the
compressor.
4
Remove the overload
protector.
(R14527)
Four way valve coil
(R14528)
Terminal cover
(R14529)
U(red)
V(yellow)
W(blue)
Overload
protector