![background image](http://html2.mh-extra.com/html/daikin/ftxn25kev1b/ftxn25kev1b_service-manual_4700136138.webp)
Outdoor Unit
SiBE041102_A
128
Removal Procedure
2. Remove the electrical box.
1
Remove the electrical
box.
3. Remove the reactor.
1
Remove the 4 screws
and remove the reactor.
4. Remove the thermistors.
Pay attention so as not to
lose the fixture.
When reassembling, do not
insert the thermistor up to
the dent of fixture.
1
Release the discharge
pipe thermistor.
Step
Procedure
Points
Electrical box
(R14516)
Reactor
(R14517)
Discharge pipe
thermistor
(R14518)
Dent
Fixture
(R11740)