![background image](http://html2.mh-extra.com/html/daikin/ftxn25kev1b/ftxn25kev1b_service-manual_4700136060.webp)
Service Check Function
SiBE041102_A
50
Service Diagnosis
3. Service Check Function
Check Method 1
1. When the timer cancel button is held down for 5 seconds,
00
indication is displayed on the
temperature display screen.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note:
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try the check
method 2. (
→
Refer to page 51.)
No.
Code
No.
Code
No.
Code
1
00
13
C7
25
UA
2
U4
14
A3
26
UH
3
L5
15
H8
27
P4
4
E6
16
H9
28
L3
5
H6
17
C9
29
L4
6
H0
18
C4
30
H7
7
A6
19
C5
31
U2
8
E7
20
J3
32
EA
9
U0
21
J6
33
AH
10
F3
22
E5
34
FA
11
A5
23
A1
35
H1
12
F6
24
E1
36
P9
(R14571)
Timer cancel button
<ARC470 Series>